Scatter correction for first-pass radiocardiography.

Nucl Med Commun

Department of Clinical Physiology, Tampere University Hospital, Finland.

Published: November 1996

The effect of the dual window scatter subtraction method was tested for first-pass radiocardiography using 99Tcm. The photopeak window of 126-154 keV (20%) and Compton window of 93-125 keV (30%) were used. The set of scattered images was multiplied by a factor of 0.4 and subtracted from the primary images. The size of the correction was tested by recalculation among a group of 16 patients sent for cardiac output studies for various reasons. The average of the percentage increase following correction was 4.0% (range -1.1 to 11.7%). The size of scatter correction was rather small in individual patients, but consistent for the group of patients as a whole. There was a statistically significant difference between the raw and corrected cardiac output values.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00006231-199611000-00009DOI Listing

Publication Analysis

Top Keywords

scatter correction
8
first-pass radiocardiography
8
group patients
8
cardiac output
8
correction first-pass
4
radiocardiography dual
4
dual window
4
window scatter
4
scatter subtraction
4
subtraction method
4

Similar Publications

Attix free-air chamber correction factors computed using EGSnrc.

Med Phys

January 2025

Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin, USA.

Background: A cylindrical free-air chamber, the Attix FAC, is used for absolute air-kerma measurements of low-energy photon beams at the University of Wisconsin Medical Radiation Research Center. Correction factors for air-kerma measurements of specific beams were determined in the 1990s. In order to measure air-kerma rates of beams in development, new correction factors must be computed.

View Article and Find Full Text PDF

The mechanical properties of metal-organic frameworks (MOFs) are of high fundamental and practical relevance. A particularly intriguing technique for determining anisotropic elastic tensors is Brillouin scattering, which so far has rarely been used for highly complex materials like MOFs. In the present contribution, we apply this technique to study a newly synthesized MOF-type material, referred to as GUT2.

View Article and Find Full Text PDF

A multiplexing method based on multidimensional readout method.

Phys Med Biol

January 2025

Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Guangqiao Load, Shenzhen, 518132, CHINA.

To develop and validate a novel multidimensional readout method that significantly reduces the number of readout channels in PET detectors while maintaining high spatial and energy performance. Approach: We arranged a 3×3×4 SiPM array in multiple dimensions and employed row/column/layer summation with a resistor-based splitting circuit. We then applied denoising methods to enhance the peak-to-valley ratio in the decoding map, ensuring accurate crystal-position determination.

View Article and Find Full Text PDF

Ultraportable (UP) X-ray devices are ideal to use in community-based settings, particularly for chest X-ray (CXR) screening of tuberculosis (TB). Unfortunately, there is insufficient guidance on the radiation safety of these devices. This study aims to determine the radiation dose by UP X-ray devices to both the public and radiographers compared to international dose limits.

View Article and Find Full Text PDF

This research examined the distinction between organic and conventional mango fruits, chips, and juice using portable near-infrared (NIR) spectroscopy. A comprehensive analysis was conducted on a sample of 100 mangoes (comprising 50 organic and 50 conventional) utilising a portable NIR spectrometer that spans a wavelength range from 900 to 1700 nm. The mangoes were assessed in their entirety and their juice and chip forms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?