A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reticulocyte quantification by Coulter MAXM VCS (volume, conductivity, light scatter) technology. | LitMetric

Reticulocyte quantification by Coulter MAXM VCS (volume, conductivity, light scatter) technology.

Clin Chem

Laboratorio Analisi Chimico-Cliniche e Microbiologiche, Ospedale Geriatrico, Padova, Italia.

Published: December 1996

In this study the ability of the Coulter MAXM analyzer to quantify reticulocytes was evaluated. The results were compared with those obtained by a microscopic method according to NCCLS H44-P recommendations and with the results from the automated analyzer Sysmex R-1000. Duplicate samples from 330 patients were analyzed. The reference intervals obtained with the three methods were: MAXM 0.37-1.80%, median 0.83%; manual 0.40-2.30%, median 1.00%; R-1000 0.60-1.95%, median 1.06%. The imprecision (CV) at all concentrations is lower than the microscopic method (low 16.1% vs 67%; normal 16.9% vs 28.9%; high 9.5% vs 13.0%). The MAXM shows a good overall correlation with the microscopic method (intercept 0.01, slope 0.89, r2 = 0.87) despite evidence of a significant overestimation at low concentrations [difference (D) 0.30] and a moderate underestimation at normal (D -0.15) and high (D -1.04) concentrations; the same behavior is shown in comparison with results from the R-1000, with an overall underestimation by MAXM (D -0.26). When compared with the microscopic method, MAXM shows a modest sensitivity at low reticulocyte counts (54.8%) and satisfactory sensitivity for high counts (87.3%), with an overall agreement of 81.3%.

Download full-text PDF

Source

Publication Analysis

Top Keywords

microscopic method
16
coulter maxm
8
compared microscopic
8
maxm
6
reticulocyte quantification
4
quantification coulter
4
maxm vcs
4
vcs volume
4
volume conductivity
4
conductivity light
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!