Heart auscultation has one of the key roles in beside diagnosis, especially in patients with cardiovascular diseases. Sometimes, because of the human cars' low sensitivity, a problem emerges in the proper evaluation of heart sounds and murmurs of lower frequencies. Our study compared two stethoscopes, the classic acoustic stethoscope (Littmann 2120) and an electronic one with the sound amplifier and the noise filtering system (Medmax2) in 10 patients examined by 10 physicians. Significantly better detection of low frequency sounds was found in favour of electronic stethoscope (chi 2 = 17.9; p < 0.0001). It is concluded that the selective amplificator improves the stethoscope performance and has its place in everyday bedside practice, especially in departments of cardiology.

Download full-text PDF

Source

Publication Analysis

Top Keywords

stethoscope
5
[comparison auscultation
4
auscultation findings
4
findings classic
4
classic stethoscope
4
stethoscope litmann
4
litmann 2120
4
2120 electronically
4
electronically amplified
4
amplified stethoscope
4

Similar Publications

A new form of stethoscope with artificial intelligence (AI) capabilities may make the difference between early detection of pregnancy-induced cardiomyopathy or end stage postpartum heart failure. The AI stethoscope is a tool that may make that difference.

View Article and Find Full Text PDF

: To compare tracheal temperature (T) with nasopharyngeal temperature (T) in patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). : T was measured using a thermistor in the cuff of an endotracheal tube and T was monitored using an esophageal stethoscope. Depending on the management of the CPB strategy, the operation was divided into four periods (pre-CPB, cooling, rewarming, and post-CPB).

View Article and Find Full Text PDF

MEMS acoustic sensors are a type of physical quantity sensor based on MEMS manufacturing technology for detecting sound waves. They utilize various sensitive structures such as thin films, cantilever beams, or cilia to collect acoustic energy, and use certain transduction principles to read out the generated strain, thereby obtaining the targeted acoustic signal's information, such as its intensity, direction, and distribution. Due to their advantages in miniaturization, low power consumption, high precision, high consistency, high repeatability, high reliability, and ease of integration, MEMS acoustic sensors are widely applied in many areas, such as consumer electronics, industrial perception, military equipment, and health monitoring.

View Article and Find Full Text PDF

A New, Easy-to-Learn, Fear-Free Method to Stop Purring During Cardiac Auscultation in Cats.

Animals (Basel)

January 2025

Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, 3584 CM Utrecht, The Netherlands.

Background: Purring in cats can interfere with cardiac auscultation. If the produced noise is loud enough, purring makes it impossible to perform a meaningful auscultation as it is much louder than heart sounds and murmurs. Our study introduced and tested a new, simple, fear-free, cat-friendly method to stop purring during auscultation.

View Article and Find Full Text PDF

Background: In recent years, there has been a significant increase in the number of patients requiring out-of-hospital intensive care. Although many of these patients are invasively ventilated, pulmonological care is often lacking. Additionally, up to 60-70% of these patients are suspected to have further potential for weaning.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!