Electrokinetic chromatography (EKC), with negatively-charged cyclodextrins (NCDs) added to the buffer, was conducted in polyacrylamide-coated columns under suppression of electroosmotic flow. The equations of migration and resolution for neutral solutes in this mode of chromatography, which for brevity we term NCD-EKC, are presented. The chiral sulfated cyclodextrin, beta-CD-SBE (IV), used in this study is anionic over the entire pH range accessible to capillary electrophoresis, and the coated columns are stable and provide reproducible performance in the pH range 2.5-8.8. Optimum separation was obtained in the pH range where the solutes are neutral. The incorporation of an alkyl spacer between the sulfate ion and the rim of the cyclodextrin allows an unhindered approach and inclusion of neutral solutes in the cyclodextrin cavity. Solute migration time is inversely proportional to the concentration of the chiral selector. Separation (relative migration time difference) increases with decreasing chiral selector concentration and approaches a maximum, beyond which further decreases in chiral selector concentration result in broad peaks and loss of resolution. A chiral selector concentration of 1% in a 10 mM phosphate buffer produced excellent separation of amino acids and dipeptide enantiomers. In addition to being chiral selectors, cyclodextrins are also known as shape selectors. NCD-EKC is particularly suited for the separation of positional isomers of hydrophobic solutes. The separation of aflatoxin isomers and chlorophenol congeners is presented. In the separation of chlorophenols the more hydrophobic trichlorophenols eluted first and the least hydrophobic, phenol, eluted last.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.1150171014DOI Listing

Publication Analysis

Top Keywords

chiral selector
16
selector concentration
12
electrokinetic chromatography
8
electroosmotic flow
8
neutral solutes
8
migration time
8
separation
7
chiral
6
chromatography suppressed
4
suppressed electroosmotic
4

Similar Publications

Computer simulation was utilized to characterize the electrophoretic processes occurring during the enantioselective capillary electrophoresis-mass spectrometry (CE-MS) analysis of ketamine, norketamine, and hydroxynorketamine in a system with partial filling of the capillary with 19 mM (equals 5%) of highly sulfated γ-cyclodextrin (HS-γ-CD) and analyte detection on the cathodic side. Provided that the sample is applied without or with a small amount of the chiral selector, analytes become quickly focused and separated in the thereby formed HS-γ-CD gradient at the cathodic end of the sample compartment. This gradient broadens with time, remains stationary, and gradually reduces its span from the lower side due to diffusion such that analytes with high affinity to the anionic selector become released onto the other side of the focusing gradient where anionic migration and defocusing occur concomitantly.

View Article and Find Full Text PDF

Background: Isotopologues resulting from the labelling of molecules with deuterium have attracted interest due to the isotope effect observed in chemistry and biosciences. Isotope effect may also play out in noncovalent interactions and mechanisms leading to intermolecular recognition. In chromatography, differences in retention time between isotopologues, as well as between isotopomers have been observed resulting in two different elution sequences (isotope effects): the normal isotope effect when heavier isotopologues retain longer than lighter analogues, and the inverse isotope effect featuring the opposite elution order.

View Article and Find Full Text PDF

Despite having identical physicochemical properties, chiral molecules require effective separation techniques due to their distinct pharmacological effects. Polysaccharide-based chiral stationary phases (CSPs) are widely used for chiral separations in liquid chromatography; however, the mechanisms of chiral recognition are not well understood. This research explored the adsorption, retention, and chiral recognition mechanisms of three amylose-based CSPs: Chiralpak ID, IF, and IG.

View Article and Find Full Text PDF

Enantioseparation and enantiorecognition are crucial in the pharmaceutical analysis of chiral substances, impacting safety, efficacy, and regulatory compliance. Enantioseparation refers to the process of separating enantiomers from a mixture, typically achieved through chromatography techniques like HPLC and SFC. In contrast, enantiorecognition involves the identification of enantiomers based on their interaction with a chiral selector without the need for separation.

View Article and Find Full Text PDF

Chiral macrocycles have emerged as attractive media for chromatographic enantioseparation due to their excellent host-guest recognition properties. In this study, a new chiral stationary phase (CSP) based on 1,1'-binaphthyl chiral polyimine macrocycle (CPM) was reported. The CPM was synthesized by one-step aldehyde-amine condensation of (S)-2,2'-dihydroxy-[1,1'-binaphthalene]-3,3'-dicarboxaldehyde with 1,2-phenylenediamine and bonded on thiolated silica via the thiol-ene click reaction to afford the CSP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!