Objective: To determine if technetium Tc 99m-labeled macroaggregated albumin selective angioscintigraphy enables estimation of microparticle-arteriovenous shunt in branchial paragangliomas and nasopharyngeal angiofibromas.

Design: Technetium Tc 99m-labeled macroaggregated albumin particles with calibrated diameters between 25 and 50 microns were administered during selective catheterization of the feeding arteries in 4 branchial paragangliomas (glomus tumors) and 4 nasopharyngeal angiofibromas. Preliminary measures of the activity of the tumor region and of the lungs were obtained in the angiography suite using a hand-held detector. Without changing the position of the microcatheter, definitive embolization was performed. After endovascular treatment, scintigraphy was performed and the pulmonary shunt index was calculated with the use of a gamma camera and a dedicated computer program.

Results: The pulmonary shunt index varied between 0% and 36% for branchial paragangliomas (glomus tumors) and between 82% and 95% for angiofibromas.

Conclusions: Our results provide new evidence that the incidence of microparticle-arteriovenous shunt in nasopharyngeal angiofibromas is much higher than in paragangliomas.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archotol.1996.01890240028007DOI Listing

Publication Analysis

Top Keywords

branchial paragangliomas
12
technetium 99m-labeled
8
99m-labeled macroaggregated
8
macroaggregated albumin
8
microparticle-arteriovenous shunt
8
paragangliomas glomus
8
glomus tumors
8
nasopharyngeal angiofibromas
8
pulmonary shunt
8
paragangliomas
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!