An in vitro dye leakage study was performed to compare the apical microleakage of Ketac-Endo root canal sealer with that of Roth's 801E and AH26 sealers. Sixty-four single-rooted human teeth were instrumented and randomly divided into four groups. Three groups were obturated with laterally condensed gutta-percha and either Roth's 801E, AH26, or Ketac-Endo as the sealer. A fourth group was obturated using a single master cone and the Ketac-Endo sealer. The teeth were suspended in 1% methylene blue dye for 6 days. The teeth were then longitudinally sectioned and evaluated for linear apical dye penetration. In general, Ketac-Endo root canal sealer showed greater dye penetration than Roth's 801E and AH26. There was no statistical difference in leakage between the laterally condensed Ketac-Endo group and the single-cone-obturated Ketac-Endo group.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0099-2399(96)80220-2DOI Listing

Publication Analysis

Top Keywords

root canal
12
canal sealer
12
roth's 801e
12
801e ah26
12
ketac-endo root
8
laterally condensed
8
ketac-endo sealer
8
dye penetration
8
ketac-endo group
8
ketac-endo
6