This study was performed in order to determine the effects of the structural configuration of prosthetic aortic valves upon coronary blood flow. A pulse-duplicating system was utilized to which a rigid model of the root of the aorta and the left artery were attached. A stented normal human valve, stented porcine valve, pivoting disc valve, tilting disc value and a caged ball valve were tested at stimulated resting conditions. The results showed that the pulse configuration and proportions of coronary flow that were systolic and diastolic changed with various valves. There was no significant reduction of the mean simulated coronary flow with the porcine valve or disc valves. Coronary flow was augmented with the caged ball valve. These differences were interpreted as being due to several fluid dynamic phenomena. These were piston effects, inertia of reversed blood flow, torque and the effects resulting from the unique pressure distribution on each valve.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bjs.1800640810DOI Listing

Publication Analysis

Top Keywords

valves coronary
12
blood flow
12
coronary flow
12
effects structural
8
structural configuration
8
configuration prosthetic
8
prosthetic aortic
8
aortic valves
8
coronary blood
8
porcine valve
8

Similar Publications

An increasing number of procedures over the past two decades for aortic stenosis (AS) reflects the combination of an aging population and less invasive transcatheter options. As a result, the hemodynamics of the aortic valve (AV) have gained renewed interest to understand its behavior and to optimize patient selection. We studied the hemodynamic relationship between pressure loss (ΔP) and transvalvular flow (Q) of the normal AV as well as the impact of a variable supravalvular stenosis.

View Article and Find Full Text PDF

Post-operative new-onset atrial fibrillation (POAF) is a possible complication following cardiac surgery. Digoxin is a drug with positive inotropic and negative chronotropic effects and is listed among antiarrhythmic drugs that can be prescribed in dogs with atrial fibrillation. This report aims at describing the use of digoxin in two dogs with persistent POAF after mitral valve repair.

View Article and Find Full Text PDF

The year 2024 has witnessed substantial advancements in interventional cardiology, encompassing both coronary and structural interventions.In coronary field, trials have explored percutaneous innovations for coronary lesions, strategies for managing post‑infarction cardiogenic shock and non‑invasive approaches for guiding revascularization. The uploaded guidelines for chronic coronary syndromes emphasize individualized care, integrating modalities such as fractional flow reserve (FFR), intravascular ultrasound (IVUS), optical coherence tomography (OCT) and new teatments, including cochicine, GLP-1 receptor agonists and bempedoic acid.

View Article and Find Full Text PDF

Unlabelled: Introduction Acute heart failure (AHF) is a life-threatening condition that requires swift diagnosis and tailored management to enhance patient outcomes. In the pursuit of more precise prognostic indicators, Tricuspid Annular Plane Systolic Excursion (TAPSE) and Pulmonary Arterial Systolic Pressure (PASP) have emerged as potential significant advancements. The TAPSE/PASP ratio, a novel parameter, has recently gained attention as a promising predictor of outcomes in acute heart failure.

View Article and Find Full Text PDF

Aims: Less pronounced calcification of the aortic valve (AVC) was observed in women with aortic stenosis (AS) as compared to men. Since women have smaller aortic valves (AV), this could explain a lower calcium load. We aimed to analyze the association of AV size with AVC independent from sex.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!