Prone carts are used for mobility by individuals with spinal cord injury who cannot use a wheelchair due to the risk of aggravating existing pressure ulcers. A prone cart is a flat/horizontal cart with a fixed height, propelled by the user while laying in a prone position. Patients reported that prolonged use of a prone cart resulted in chronic neck, shoulder and back pain. Additionally the existing prone carts lack user accessible angle adjustability, chest support area, as well as a storage, eating or working area. An interdisciplinary research team collaborated to address these concerns. Three prone carts were evaluated: E&J, Gendron, and a newly developed prototype, MIAD/PVA. Questionnaires were administered to caregivers and patients regarding usage and effectiveness of the prone carts as well as the features of an ideal cart. This data led to the design and refinement of a prototype prone cart which was tested on 20 patients and 19 caregivers at the SCI Centers of the Milwaukee and Tampa VAMC's from 1994-1995. The new prone cart enables the user to lie at an angle rather than laying flat. This position has been found to relieve back and neck pressure. With an hydraulic system, the the user can adjust both the front and rear angles of the cart to achieve desired comfort. In addition, a front deck provides an eating and working area. This study resulted in research-based information and criteria for the design of new prone carts. Findings of this pilot study will be incorporated in a development merit review proposal to the VA Rehabilitation Research & Development service for the design of a new manual and motorized prone cart. The researchers are collaborating with Ortho-Kinetics Inc. to promote ease in manufacturing.
Download full-text PDF |
Source |
---|
Animals (Basel)
December 2024
Key Laboratory of New Animal Drug Project of Gansu Province, Key Laboratory of Veterinary Pharmaceutical Development, Ministry of Agriculture and Rural Affairs, Lanzhou Institute of Husbandry and Pharmaceutical Sciences, Chinese Academy of Agricultural Sciences (CAAS), Lanzhou 730050, China.
The aim of this study was to determine the prevalence and association of EGUS in horses of different ages, breeds and occupations. Gastroscopies were performed on 395 horses, and gastric ulcers were graded on a scoring system from 0 to 4. The relationship between age, breed, and work, along with the prevalence of gastric ulcers and their influences, were evaluated.
View Article and Find Full Text PDFJ Rehabil Res Dev
April 2018
Spinal Cord Injury Unit, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH;
Pressure ulcers remain a major source of morbidity and mortality in Veterans with neurologic impairment. Management of pressure ulcers typically involves pressure relief over skin regions containing wounds, but this can lead to loss of mobility and independence when the wounds are located in regions that receive pressure during sitting. An innovative, iterative design process was undertaken to improve prone cart design for persons with spinal cord injury and pressure ulceration.
View Article and Find Full Text PDFAppl Ergon
October 2010
Department of Biological and Agricultural Engineering, University of California Agricultural Ergonomics Research Center, Western Center for Agricultural Health and Safety, Davis, CA 95616, USA.
This paper gives an overview of the extent of musculoskeletal disorders (MSDs) in agriculture, and a historical perspective on how ergonomics has been used to reduce the health effects of labor-intensive agriculture. A summary of exposure to MSD physical risk factors within various classes of crops, along with various administrative and engineering controls for abating MSDs in agriculture is given. These controls range from programmed rest breaks to mechanized or partially-mechanized operations.
View Article and Find Full Text PDFJ Spinal Cord Med
May 2007
Patient Safety Center 118M, James J. Haley Veterans Hospital, Tampa, FL 33162-5735, USA.
Background/objective: Prone carts are used for mobility by individuals with spinal cord injury in whom seated mobility (wheelchair) is contraindicated due to ischial or sacral pressure ulcers. Currently available prone carts are uncomfortable, subjecting the user to neck and shoulder strain, and make social interaction and performing activities of daily living difficult. A better design of prone carts is needed.
View Article and Find Full Text PDFJ Rehabil Res Dev
September 2002
Research Service, Clement J. Zablocki Veterans Affairs Medical Center (VAMC), Milwaukee, WI 53295-1000, USA.
This paper summarizes a series of projects funded since 1992 to address the compelling need to improve the quality of life for persons with spinal cord dysfunctions who use prone carts. Specifically, Veterans Services Organization, National Institute on Disability and Rehabilitation Research (NIDRR), and the VA Rehabilitation Research and Development funded studies to develop new consumer-driven designs for prone carts. Using an iterative approach, this team of clinicians and designers (1) evaluated existing prone carts; (2) designed a new manual prone cart; (3) designed a new motorized prone cart, including a standing model; and (4) are collaborating with manufacturers to market and commercialize the new prone carts.