A miniature, interstitial x-ray generator has recently been developed and is currently undergoing clinical trials for the treatment of brain tumors. The maximum photon energy from this x-ray tube is 50 keV, although most of the initial testing has been carried out at 40 keV. Dose rates of up to 2 Gy/min in a water phantom at a distance of 10 mm from the tube tip are produced. In this paper we describe the modeling and simulation of x-ray production from this device using the ITS 3.0 Monte Carlo code. Verification of the simulation of x-ray production in the device was carried out by comparing predictions of spatial photon distribution, energy spectrum, and dose versus depth in water with experimentally obtained measurements. Agreement between the simulated results and experimental measurements was fairly good when comparing the angular distribution of photons emitted from the x-ray tube and very good when comparing dose rate versus depth in a water phantom. Discrepancies observed when comparing the calculated and measured estimates of characteristic line radiation were reduced by incorporation of a modification to the ITS code. Possible causes of the remaining discrepancy in bremsstrahlung intensity are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.597885DOI Listing

Publication Analysis

Top Keywords

x-ray tube
12
monte carlo
8
water phantom
8
simulation x-ray
8
x-ray production
8
production device
8
versus depth
8
depth water
8
good comparing
8
x-ray
6

Similar Publications

Background: The spatial resolution of new, photon counting detector (PCD) CT scanners is limited by the size of the focal spot. Smaller, brighter focal spots would melt the tungsten focal track of a conventional X-ray source.

Purpose: To propose focal spot multiplexing (FSM), an architecture to improve the power of small focal spots and thereby enable higher resolution clinical PCD CT.

View Article and Find Full Text PDF

Introduction: Echinococcus is a common infection in an endemic country like Bhutan. Mediastinal echinococcosis is rare. Although presentation due to a mediastinal echinococcal cyst is variable according to the cyst's location, a reaction due to rupture of the cyst and simultaneous reaction to an administration of antibiotics such as ceftriaxone can cause a diagnostic challenge.

View Article and Find Full Text PDF

Dynamic pathophysiological features of early primary blast lung injury: a novel functional incapacity pig model.

Eur J Trauma Emerg Surg

January 2025

Department of Military Traffic Injury Prevention and Control, Daping Hospital, Army Medical University, Chongqing, 400042, China.

Introduction: While there is evidence supporting the use of ultrasound for real-time monitoring of primary blast lung injury (PBLI), uncertainties remain regarding the timely detection of early PBLI and the limited data correlating it with commonly used clinical parameters. Our objective is to develop a functional incapacity model for PBLI that better addresses practical needs and to verify the early diagnostic effectiveness of lung ultrasound in identifying PBLI.

Methods: We selected six healthy male pigs to develop an animal model using a bio-shock tube (BST-I).

View Article and Find Full Text PDF

Ultraportable (UP) X-ray devices are ideal to use in community-based settings, particularly for chest X-ray (CXR) screening of tuberculosis (TB). Unfortunately, there is insufficient guidance on the radiation safety of these devices. This study aims to determine the radiation dose by UP X-ray devices to both the public and radiographers compared to international dose limits.

View Article and Find Full Text PDF

We report a case of a 74-year-old female with a retrosternal goiter undergoing video-assisted thoracic surgery (VATS) for a left lung lower lobectomy, necessitating one-lung ventilation (OLV). We encountered a highly unusual complication: contralateral tension pneumothorax. Forty-five minutes into the surgical procedure, a sudden cardiovascular collapse occurred.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!