Purpose: To evaluate the effects of tracking and volume of contrast material on dual-phase helical computed tomography (CT) of the liver.

Materials And Methods: CT was performed in 120 consecutive patients. Either 100 mL (groups 1 and 2) or 120 mL (groups 3 and 4) of contrast material was injected at a rate of 4 mL/sec. In groups 1 and 3, the scanning delay was fixed, whereas in groups 2 and 4, scanning delays were determined individually by means of a semiautomatic bolus tracking device. The arterial phase began when splenic enhancement was greater than 10 HU and ended when hepatic enhancement was greater than 20 HU, which characterized the start of the portal venous phase.

Results: The mean duration of the arterial phase was 11.6 (100 mL) and 12.2 seconds (120 mL). The arterial phase of the liver within the defined limits was sufficiently timed in only 16 (54%) patients in group 1, 25 (83%) in group 2, and 20 (67%) in groups 3, whereas it was significantly (P < .05) better in 28 (93%) patients in group 4. A significantly (P < .05) higher mean parenchymal enhancement in the portal venous phase (63.6 HU +/- 8.5) was obtained in group 4.

Conclusion: Bolus tracking of a volume of 120 mL provided the most accurate results in dual-phase liver CT.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.201.2.8888218DOI Listing

Publication Analysis

Top Keywords

bolus tracking
12
contrast material
12
arterial phase
12
dual-phase helical
8
tracking volume
8
groups scanning
8
enhancement greater
8
portal venous
8
patients group
8
groups
5

Similar Publications

Multidetector-row computed tomographic angiography (angio-CT) aims to achieve optimal opacification of the vascular compartment of interest. The distribution and quality of vascular opacification are influenced by patient-related factors, contrast medium (CM)-related factors, and scanner-related factors. This systematic review evaluates these factors and their effects on contrast enhancement.

View Article and Find Full Text PDF

The study investigates the economics of sensor-assisted dairy health management and indicates a certain economic potential in the use of a commercial rumen bolus capable of tracking activity and core body temperature. The economic evaluation was performed applying a stochastic model with the net return (NR) of investment of the sensor system as the target variable. The calculated NR considers the gross margin (GM) for both sensor-assisted and visual health monitoring, time savings through sensor-assisted monitoring, additional time spent addressing false positive messages from the sensor system, labor costs, and all costs associated with the investment in the sensor system.

View Article and Find Full Text PDF

Introduction: Differentiating pheochromocytomas from other adrenal masses based on computed tomography (CT) characteristics remains challenging, particularly in lipid-poor lesions with variable washout patterns. This study evaluated CT features for distinguishing pheochromocytomas in good and poor washout subcohorts.

Methods: We prospectively analyzed 72 patients with unilateral lipid-poor adrenal masses.

View Article and Find Full Text PDF

Glioblastomas (GBMs) are dreadful brain tumors with abysmal survival outcomes. GBM extracellular vesicles (EVs) dramatically affect normal brain cells (largely astrocytes) constituting the tumor microenvironment (TME). We asked if EVs from different GBM patient-derived spheroid lines would differentially alter recipient brain cell phenotypes.

View Article and Find Full Text PDF

Angiographic reconstructions of CT perfusion for occlusion detection in ischemic stroke.

Eur J Radiol

December 2024

Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, the Netherlands; Mental Health and Neuroscience Research Institute (MHeNs), University Maastricht, Maastricht, the Netherlands.

Background: Both CT angiography and CT perfusion involve the administration and tracking of a contrast medium bolus for different purposes. In this study, we aim to compare the diagnostic accuracy and subjective image quality of CTP-angiographic reconstructions with conventional CTA for occlusion detection in ischemic stroke patients.

Methods: In this retrospective study, patients with a final diagnosis of ischemic stroke and who underwent both CTA and CTP from September 2020 up to and including September 2021 were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!