The aim of this study was to determine the diagnostic efficiency of transesophageal echocardiography (TEE) in isthmic aortic ruptures and to describe the echocardiographic Doppler anomalies. TEE was performed prospectively for 18 months in 33 patients with serious polytraumas requiring intensive care. The average age was 40.75 years (range, 17 to 78 years). Single or biplanar TEE was used. In three patients with aortic transection, echocardiography showed an intimal flap thicker than that of dissections. The flaps were torn and retracted on the free edge. It was difficult to distinguish the periaortic hematoma. Doppler imaging showed turbulent flows in several places around the aorta. These flows were especially visible at the beginning of the intimal flap. They were visible on M-mode color imaging during systole and diastole. During diastole, a large color flow was observed in the middle of the aortic lumen. It was turbulent in some places and mimicked the systolic filling of the aorta. These flows create the characteristic "to and fro sign" spectrum of Doppler imaging, usually seen in peripheral false arterial aneurysms. TEE findings were confirmed in two cases by surgery and in one case by aortography. TEE seems to be an effective means of detecting isthmic rupture, with the diagnosis resting on the data obtained from echocardiography and Doppler imaging. A suspected isthmic disruption should be assessed by an emergency TEE and aortography used only for uncertain or complex cases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0894-7317(96)90061-9DOI Listing

Publication Analysis

Top Keywords

doppler imaging
12
aortic ruptures
8
transesophageal echocardiography
8
intimal flap
8
aorta flows
8
tee
6
traumatic aortic
4
ruptures diagnosed
4
diagnosed transesophageal
4
echocardiography
4

Similar Publications

Background: Ultrasound lung surface motion measurement is valuable for the evaluation of a variety of diseases. Speckle tracking or Doppler-based techniques are limited by the loss of visualization as a tracked point moves under ribs or is dependent.

Methods: We developed a synthetic lateral phase-based algorithm for tracking lung motion to overcome these limitations.

View Article and Find Full Text PDF

Objective: To evaluate whether, in late pregnancy, the cerebral Doppler can identify very small fetuses that are less likely to experience intrapartum compromise (IC).

Material And Methods: This was a retrospective study of 282 singleton pregnancies that underwent an ultrasound scan at 32 + 0- 40 + 6 weeks and were delivered after induction, or spontaneous onset of labor. Very small fetuses were defined as fetuses with estimated weight less than the 3rd centile.

View Article and Find Full Text PDF

Topographical Mapping of Metabolic Abnormalities in Multiple Sclerosis using Rapid Echo-less 3D-MR Spectroscopic Imaging at 7T.

Neuroimage

January 2025

High-Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for MR Imaging Biomarkers (BIOMAK), Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.

Objectives: To assess topographical patterns of metabolic abnormalities in the cerebrum of multiple sclerosis (MS) patients and their relationship to clinical disability using rapid echo-less 3D-MR spectroscopic imaging (MRSI) at 7T.

Materials And Methods: This study included 26 MS patients (13 women; median age 34) and 13 age- and sex-matched healthy controls (7 women; median age 33). Metabolic maps were obtained using echo-less 3D-MRSI at 7T with a 64 × 64 × 33 matrix and a nominal voxel size of 3.

View Article and Find Full Text PDF

Objective: The Achilles' heel of infrainguinal bypass grafts (IIBG) is restenosis. Duplex ultrasound (DUS) surveillance is commonly undertaken to identify restenosis allowing intervention for graft salvage. We report the impact of DUS surveillance on patient outcomes alongside healthcare-associated costs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!