Feasibility of simultaneous 2D-Echo and SPECT Tc99m Sestamibi imaging during dobutamine infusion was evaluated in a female population with suspected coronary artery disease and scheduled for diagnostic coronary angiography. A total of 49 consecutive subjects were studied. Patients under continuous ECG and 2D-Echo monitoring underwent standard dobutamine infusion at increasing doses to a diagnostic end-point. Tc99m Sestamibi was administered at the peak of the dobutamine effect. With this approach, 35 patients were identified correctly by 2D-Echo (Sensitivity = 60.1%; Specificity = 83.3%; Agreement = 71.4%; k = 0.43). Perfusion imaging with Tc99m Sestamibi resulted in correctly identifying 41 patients (Sensitivity = 83%; Specificity = 84%; Agreement = 83.6%; k = 0.67). Combining information obtained from the two tests resulted in increased specificity (92%) and decreased sensitivity (64%). Simultaneous assessment of perfusion and function with Tc99m Sestamibi and 2D-Echo imaging during dobutamine administration is easily performed without added risk or discomfort to the patient. Tc99m Sestamibi appeared to be slightly superior to 2D-Echo for the detection of CAD in this population, but the difference does not reach conventional statistical significance. The combined use of the two independent tests did not substantially improve the diagnostic accuracy of each method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF01880742 | DOI Listing |
Front Oncol
December 2024
Department of Nuclear Medicine, The Second Affiliated Hospital of Soochow University, Suzhou, China.
Purpose: Parathyroid carcinoma (PC) is an extremely rare disease, typically presenting with marked elevations of serum calcium concentrations and associated with significantly increased parathyroid hormone (PTH) levels. Although it progresses slowly, approximately25% of PC patients have lung metastases. In the present study, we aimed to evaluate the role of technetium-99m methoxy isobutyl isonitrile (Tc-99m-MIBI; sestamibi) SPECT/CT scintigraphy in the preoperative localization of parathyroid adenomas, incidental metastases findings of PC, and ectopic parathyroid tissue.
View Article and Find Full Text PDFJ Otolaryngol Head Neck Surg
December 2024
Department of Otolaryngology-Head and Neck Surgery, Jewish General Hospital, Montreal, Canada.
Background: Minimally invasive parathyroidectomy (MIP) in patients with a parathyroid adenoma (PA) requires imaging modalities for precise localization. Parathyroid hormone assay on ultrasound-guided fine-needle aspiration washout, or PTH washout, can be used for this purpose. It is unclear whether PTH washout complements traditional PA localization techniques such as a sestamibi (MIBI) scan or diminishes its need.
View Article and Find Full Text PDFJ Breast Imaging
December 2024
Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Molecular breast imaging (MBI) is a functional imaging modality that utilizes technetium 99m sestamibi radiotracer uptake to evaluate the biology of breast tumors. Molecular breast imaging can be a useful tool for supplemental screening of women with dense breasts, for breast cancer diagnosis and staging, and for evaluation of treatment response in patients with breast cancer undergoing neoadjuvant systemic therapy. In addition, MBI is useful in problem-solving when mammography and US imaging are insufficient to arrive at a definite diagnosis and for patients who cannot undergo breast MRI.
View Article and Find Full Text PDFRadiol Oncol
December 2024
Division of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!