Compression? Yes, but for low or high frequencies, for low or high intensities, and with what response times?

Ear Hear

National Acoustic Laboratories, Chatswood, Australia.

Published: August 1996

Several rationales for using compression in hearing aids are outlined. These rationales comprise discomfort avoidance, loudness normalization, noise reduction, short term signal dynamic range reduction, empirically determined compression, and long-term signal dynamic range reduction. The compression systems needed to implement each of these differ greatly, and these differences can be viewed as differences in the frequency range undergoing most compression, the intensity range undergoing most compression, and the speed at which the compressor(s) operate. A classification system along these lines is introduced and examples of currently available hearing aids falling into each category are given. The effects of each type of compression on speech intelligibility is investigated via a review of published research. The results of this indicate that, for speech in quiet at a comfortable level, no compression scheme yet tested offers better intelligibility than individually selected linear amplification. If input level is then decreased and the aid wearer is prevented from adjusting the volume control, many types of compression provide intelligibility superior to that available from linear amplification. In broadband noise, only one system, containing wideband compression followed by fast acting high-frequency compression, has so far been shown to provide significant intelligibility advantages.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00003446-199608000-00001DOI Listing

Publication Analysis

Top Keywords

compression
10
low high
8
hearing aids
8
signal dynamic
8
dynamic range
8
range reduction
8
range undergoing
8
undergoing compression
8
linear amplification
8
compression provide
8

Similar Publications

Otherwise, inoperable. The role of ECMO in thoracic surgery - focus on the mediastinum.

Port J Card Thorac Vasc Surg

January 2025

Thoracic surgeon, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milano, Italy.

The use of extracorporeal membrane oxygenation (ECMO) in surgery is expanding as the medical community started adopting it, with good results, for procedures with high risk of respiratory and hemodynamic instability. This technique provided the possibility to reduce the number of patients previously considered inoperable because of these limitations. Thymic epithelial tumors (TETs) are rare neoplastic mediastinal lesions, with a reported incidence of 0.

View Article and Find Full Text PDF

Recently, 3-D porous architecture of the composites play a key role in cell proliferation, bone regeneration, and anticancer activities. The osteoinductive and osteoconductive properties of β-TCP allow for the complete repair of numerous bone defects. Herein, β-TCP was synthesized by wet chemical precipitation route, and their 3-D porous composites with HBO and Cu nanoparticles were prepared by the solid-state reaction method with improved mechanical and biological performances.

View Article and Find Full Text PDF

Uniaxial compression experiments were conducted on coal rock utilizing a computed tomography (CT) scanning system for real-time monitoring to explain the issue of gas volume significantly exceeding reservoir capacity during coal and gas outbursts. A percolation factor a which can make a significant contribution to the research on premonitory information of gas outbursts is introduced to determine whether percolation occurs in coal rock, and supports the outburst percolation theory. It was found that percolation probability and correlation length increase with greater porosity, and that the number of pore clusters decreases as porosity increases.

View Article and Find Full Text PDF

Acoustical properties are essential for understanding the molecular interactions in fluids, as they influence the physicochemical behavior of liquids and determine their suitability for diverse applications. This study investigated the acoustical parameters of silver nanoparticles (Ag NPs), reduced graphene oxide (rGO), and Ag/rGO nanocomposite nanofluids at varying concentrations. Ag NPs and Ag/rGO nanocomposites were synthesized via a Bos taurus indicus (BTI) metabolic waste-assisted method and characterized using advanced techniques, including XRD, TEM, Raman, DLS, zeta potential, and XPS.

View Article and Find Full Text PDF

Pocket hematoma is a common and serious complication following cardiac implantable electronic device (CIED) implantation, contributing to significant morbidity and mortality. This study aimed to evaluate the efficacy of a novel pocket compression device in reducing pocket hematoma occurrence. We enrolled 242 patients undergoing CIED implantation, randomly assigning them to receive either the novel compression vest with a pressure cuff or conventional sandbag compression.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!