Skin penetration and sun protection factor of ultra-violet filters from two vehicles.

Pharm Res

Department of Biopharmacy, Spirig AG, 4622 Egerkingen, Switzerland.

Published: May 1996

Purpose: In order to improve our knowledge on the efficacy and safety of sunscreen products, we measured the skin penetration profiles of ultra-violet (UV) filters in vitro and in vivo, and the corresponding sun protection factors (SPF) from two vehicles (an O/W emulsion-gel and petroleum jelly).

Methods: The UV filters tested were oxybenzone (5%, A), 2-ethylhexyl 4-methoxycinnamate (7.5%,B), and 2-ethylhexylsalicylate (3%,C). Two mg/cm(2) were applied for 2 min to 6 h. In vitro penetration measurements were performed with static diffusion cells. In vivo, horny layer concentrations were measured after stripping and the SPF evaluated as recommended by the COLIPA-guidelines.

Results: Significant differences between vehicles were noticed in vitro as well as in vivo. In vitro, the emulsion-gel generated higher epidermal concentrations than petroleum jelly. Values at 6 h, expressed as percent of the applied dose for A, B, and C were 4, 9, and 7% for the emulsion-gel and 2, 1, and 2% for petroleum jelly. An opposite trend was noticed, mainly for A, in the deeper skin layers with concentrations of 2% in the dermis and 5% in the receptor fluid for petroleum jelly and 0.6% and 1% for the emulsion-gel respectively. In vivo, for each UV filter, maximal stratum corneum levels (15 strips) were obtained at 0.5 h with percentages of the applied doses of 50% for the emulsion-gel and 15 percent for petroleum jelly. SPFs, measured 0.5 h after application amounted to 14 for the emulsion-gel and 5 for petroleum jelly, and decreased in both cases by a factor 2.2 after removal of non penetrated product.

Conclusions: These preliminary results demonstrated that UV filters penetration and retention as well as expected SPF could be optimized by a suitable vehicle.

Download full-text PDF

Source
http://dx.doi.org/10.1023/a:1016012019483DOI Listing

Publication Analysis

Top Keywords

petroleum jelly
20
emulsion-gel petroleum
12
skin penetration
8
sun protection
8
ultra-violet filters
8
emulsion-gel
6
petroleum
6
jelly
5
penetration sun
4
protection factor
4

Similar Publications

Purpose: Solid crystalline spin probes, such as lithium phthalocyanine (LiPc) and lithium octa-n-butoxynaphthalocyanine (LiNc-BuO), allow repeated oxygen measurement using electron paramagnetic resonance (EPR). Due to their short relaxation times, their use for pulse EPR oxygen imaging is limited. In this study, we developed and tested a new class of solid composite spin probes that modified the relaxation rates R and R of LiPc or LiNc-BuO probes, which allowed pO measurements in the full dynamic (0-760 torr) range.

View Article and Find Full Text PDF

Combined negative pressure wound therapy with new wound dressings to repair a ruptured giant omphalocele in a neonate: a case report and literature review.

BMC Pediatr

January 2025

Department of Neonatology Nursing, West China Second University Hospital, Sichuan University, No. 20, Section 3, South Renmin Road, Chengdu, Sichuan Province, China.

Background: Current treatment of giant omphalocele in newborns is not standardized. The main treatments include one-time repair and staged surgery using synthetic and biologic mesh, or silos. However, surgery can lead to various postoperative complications.

View Article and Find Full Text PDF

Introduction: Opportunistic infections (IO) are infections of microbiota (fungi, viruses, bacteria, or parasites) that generally do not cause disease but turn into pathogens when the body's defense system is compromised. This can be triggered by various factors, one of which is due to a weakened immune system due to Diabetes Mellitus (DM), which increases the occurrence of opportunistic infections, especially in the oral cavity. Fungal (oral candidiasis) and viral (recurrent intraoral herpes) infections can occur in the oral cavity of DM patients.

View Article and Find Full Text PDF

: The aim is to bring attention to the existence of a rare type of trauma of the hand, high-pressure injection injury, that appears to be minor with negligible signs and symptoms within the first hours after the accident, but in reality, produces significant tissue destruction with severe consequences. Recognizing this type of trauma by medical personnel, understanding the mechanisms involved, and knowing the etiological and prognostic factors can lead to early treatment initiation and avoid severe mutilating sequelae. : A retrospective study on 16 patients diagnosed with high-pressure injection injuries, including water, air, paint, paint mixed paint with thinner, petroleum jelly, and lime (washable paint containing calcium oxide).

View Article and Find Full Text PDF

Exogenous Lipoid Pneumonia after Long-Term Nasal Petroleum Jelly Application.

Radiol Cardiothorac Imaging

February 2025

From the Department of Diagnostic and Interventional Radiology (D.B., M.H.P.) and Department of Pathology and Cytology (S.S.J.), University Hospital Center Zagreb, Kišpatićeva 12, 10 000 Zagreb, Croatia; Clinic for Lung Diseases Jordanovac, University Hospital Center Zagreb, Zagreb, Croatia (M.K.); and University of Zagreb School of Medicine, Zagreb, Croatia (M.K., S.S.J., M.H.P.).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!