Echocardiographic clues and accuracy in the diagnosis of scimitar syndrome.

J Am Soc Echocardiogr

Division of Cardiology, the Hospital of Sick Children, Toronto, Ontario, Canada.

Published: February 1997

Scimitar syndrome was diagnosed in 27 patients seen between July 1974 and May 1993. All available echocardiograms taken before surgery or death were reviewed. Age at presentation ranged from 1 day to 14 years. Dextrocardia or mesocardia was noted in 70%, atrial septal defect in 70%, and increased right ventricular dimension in 70% of the patients. The ratio of the proximal and distal diameters of the right/left pulmonary arteries were reduced 0.68 +/- 0.17 and 0.66 +/- 0.17, respectively. "Blunting" of the right side of the left atrium was seen in all patients with total anomalous right pulmonary venous drainage and none with partial drainage. Anomalous right pulmonary venous drainage was characterized in 91% of echocardiograms with color flow mapping versus 14% without color flow mapping (p < 0.0002). Aortopulmonary collateral arteries were detected in all four cases in which color flow mapping was performed, but not detected otherwise.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0894-7317(96)90025-5DOI Listing

Publication Analysis

Top Keywords

color flow
12
flow mapping
12
scimitar syndrome
8
+/- 017
8
anomalous pulmonary
8
pulmonary venous
8
venous drainage
8
echocardiographic clues
4
clues accuracy
4
accuracy diagnosis
4

Similar Publications

The involvement of axillary lymph nodes (ALNs) is a critical prognostic factor affecting patient management and outcomes in breast cancer (BC). This study aims to comprehensively analyze the clinical data of BC patients, evaluate ultrasonic signs of ALNs, and explore the implications of a prediction model for ALN metastasis (ALNM) in early-stage BC patients based on ultrasonic features and clinical data. This study retrospectively analyzed ultrasonic features and clinical data from 216 patients diagnosed with unilateral invasive BC.

View Article and Find Full Text PDF

Purpose: The present study aimed to assess the impact of diabetes mellitus and smoking in orbital vessels, utilizing resistive index (RI) through color Doppler imaging (CDI).

Materials And Methods: The cross-sectional study consisted of 90 participants divided into three groups of 30 each. Group A consisted of normal individuals, Group B consisted of patients with diabetes, and Group C consisted of patients with a history of diabetes and smoking.

View Article and Find Full Text PDF

Zebra stripes induce aberrant motion analysis in flies through aliasing.

J Exp Biol

January 2025

Independent researcher, 74 Eccleston Square, London, UK.

The function of zebra stripes has long puzzled biologists: contrasted and conspicuous colours are unusual in mammals. The puzzle appears solved: two lines of evidence indicate that they evolved as a protection against biting flies, the geographical coincidence of stripes and exposure to trypanosomiasis in Africa and field experiments showing flies struggling to navigate near zebras. A logical mechanistic explanation would be that stripes interfere with flies' analysis of the optic flow; however, both spatio-temporal aliasing and the aperture effect seem ruled out following recent experiments showing that randomly checked patterns also interfere with flies' capacity to navigate near zebras.

View Article and Find Full Text PDF

Objective: Photosensitivity occurs in ~75% of lupus patients. Although ultraviolet light radiation (UVR) stimulates Type I interferon (IFN-I) in the skin, how UVR induced skin inflammation leads to downstream effects is poorly understood. Tissue inflammation causes DC to migrate from organs to draining lymph nodes (dLN) including a recently identified inflammatory DC subset (inf cDC2) that are potent antigen presenting cells.

View Article and Find Full Text PDF

Quantitative investigation of a 3D bubble trapper in a high shear stress microfluidic chip using computational fluid dynamics and L*A*B* color space.

Biomed Microdevices

January 2025

Chakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, 111 Suwannabhumi Canal Rd, Bang Pla, Bang Phli District, Samut Prakan, 10540, Thailand.

Microfluidic chips often face challenges related to the formation and accumulation of air bubbles, which can hinder their performance. This study investigated a bubble trapping mechanism integrated into microfluidic chip to address this issue. Microfluidic chip design includes a high shear stress section of fluid flow that can generate up to 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!