We studied posterior cruciate ligament reconstruction in a cadaveric model using two substitutes: a 1-mm diameter flexible cable and an 11-mm diameter Achilles tendon autograft. The thin cable allowed us to study five femoral and five tibial attachments in each knee. A nearly isometric attachment was located after cutting the posterior cruciate ligament while the tibia was reduced with a 100 N anterior force. The five femoral locations studied were the isometric location and four locations centered around this isometric point. The Achilles tendon reconstruction was used with both an isometric and a nonisometric femoral site, allowing us to confirm the results with the wire cable. Posterior motion limits were measured under a 100 N posterior force in the intact, posterior cruciate ligament-deficient, and posterior cruciate ligament-reconstructed knees. We found that the restoration of knee stability in flexion depended strongly on the femoral attachment location. A femoral attachment that was nonisometric by intraoperative measurement, but within the posterior cruciate ligament anatomic footprint, most closely reproduced the intact knee's posterior motion limits. Variations in the tibial attachment site produced only minor changes in the posterior motion limits. We concluded that the proximal-distal location selected for the femoral attachment of a posterior cruciate ligament substitute was particularly important in the restoration of normal posterior motion limits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/036354659602400406 | DOI Listing |
BMC Musculoskelet Disord
January 2025
Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo City, Japan.
Background: Bicruciate-retaining (BCR) prostheses have been introduced to recreate normal knee movements by preserving both the anterior and posterior cruciate ligaments. One of the surgical procedures essential to the success of BCR total knee arthroplasty (TKA) is preservation of the tibial eminence. However, in our clinical experience, we found that a well-preserved tibial eminence changed its shape chronologically after the operation.
View Article and Find Full Text PDFSICOT J
January 2025
Department of Orthopaedic Surgery, Joint Replacement Unit, Kuala Lumpur Hospital, Ministry of Health Malaysia, Jalan Pahang, 50586 Kuala Lumpur, Malaysia.
Introduction: Extraarticular deformity (EAD) with knee arthritis is a complex condition involving tri-planar bone deformity with pathological malalignment and chronic soft tissue contracture or laxity in the knee joint. Intraarticular correction by TKA, which was previously performed with conventional manual jig by mechanical alignment technique, had its limits and difficulties especially extensive soft tissue release and risk of jeopardizing the collateral ligaments. Robotic technology allows for reproducible and precise execution of surgical plan and allows adjustment to various new personalised alignment philosophy including functional alignment (FA).
View Article and Find Full Text PDFJ Orthop Case Rep
January 2025
Department of Orthopaedics, SN Medical College, Agra, Uttar Pradesh, India.
Introduction: Posterior cruciate ligament (PCL) avulsion fractures of the tibia with ipsilateral tibial shaft represent a rare but challenging orthopedic injury, necessitating careful consideration of surgical interventions for optimal outcomes. This case report presents the successful management of tibial shaft fracture (proximal 1/3rd junction) along with ipsilateral PCL avulsion fracture of tibia using a novel approach using open reduction internal fixation (ORIF) of tibial shaft with Locking compression plate (LCP) with cannulated cancellous screw and spiked washer fixation of PCL avulsion. There are no case reports or research articles available for the management of PCL avulsion fracture of tibia associated with ipsilateral tibial shaft fracture.
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, Maebashi, Japan.
Introduction: Stair ascent and descent are physically demanding tasks requiring higher functional ability of the lower extremity muscles and joint range of motion than level walking, and are associated with patient satisfaction after total knee arthroplasty (TKA). This study aimed to investigate stair ascent and descent ability after cruciate-retaining (CR)-TKA using the patient-reported outcomes, and to examine the role of knee sagittal stability and handgrip strength in postoperative stair ascent and descent ability.
Materials And Methods: This study included 84 female patients who underwent primary unilateral CR-TKA for knee osteoarthritis at our institute between April 2015 and February 2019.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao
December 2024
Department of Sport and Rehabilitation Medicine,Beijing Chao-Yang Hospital, Capital Medical University,Beijing 100020,China.
Objective To investigate the effects of rotation stability after anterior cruciate ligament reconstruction (ACLR) on subjective outcomes,sport performance,psychological readiness,and return to sport. Methods The patients who underwent ACLR in the Sports Hospital,National Institute of Sports Medicine,General Administration of Sport of China from January 2015 to January 2021 were followed up during the period from November 2022 to December 2023.The patients were grouped according to the results of the pivot shift test (PST) of the affected knee at the last follow-up visit.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!