Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A prospective study was carried out to determine the usefulness of 99TCm-human immunoglobulin G (HIG) scintigraphy in the assessment of the severity of joint inflammation. Twenty-four patients with rheumatoid arthritis were studied. The presence or absence of pain and/or swelling was evaluated in 34 joints and a clinical index taking into account the surface area of each joint was calculated. We measured the following biological markers of inflammation activity: erythrocyte sedimentation rate, C-reactive protein, haemoglobin, platelet count, serum levels of IL-6, TNF-alpha and soluble receptors of IL-2. Scintigraphic was performed 4 h after the injection of 740 MBq 99Tcm-HIG. The scans were evaluated by visual and quantitative analysis and the scores in each joint were weighted for joint size. Pathological uptake of the radiopharmaceutical was noted in 46% (24/52) of joints evaluated as painful, 89% (146/164) of swollen joints and 94% (78/83) of both painful and swollen joints. Both the visual and the quantitative scintigraphic indices correlated significantly with the clinical index, the number of painful joints, the number of swollen joints and several biological markers of inflammation. A very high correlation was also found between the visual and the quantitative scintigraphic indices (r = 0.91, P < 0.0001). In conclusion, 99Tcm-HIG scintigraphy is an objective test to detect synovitis and to assess the severity of inflammation. A careful visual analysis of scans is good enough for routine evaluations and computer quantitative analysis should be used when more accurate intra-individual variation is required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00006231-199606000-00012 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!