Objective: To investigate the diagnostic accuracy of screening serum P in diagnosis of ectopic pregnancy (EP) and to identify a cutoff value that provides the best compromise between test sensitivity and specificity.

Design: Retrospective analysis.

Setting: University hospital.

Interventions: Observation only.

Patients: First trimester pregnant women at risk for EP.

Main Outcome Measure: Single P measurements were obtained from 3,674 pregnancies with outcomes defined as EP, viable intrauterine pregnancy (IUP), and spontaneous abortion (SAB). Diagnostic accuracy of the test was analyzed by generating receiver operating characteristic (ROC) curves, which quantify the ability of the test to distinguish EP and SAB from IUP.

Results: Diagnostic accuracy for EP versus IUP was 88.7% +/- 0.1% (mean +/- SEM); for SAB versus IUP, 93.8% +/- 0.4%; and for SAB + EP versus IUP, 92.8% +/- 0.4%. Diagnostic accuracy for SAB versus EP was only 39.4% +/- 0.2%. In the interval of 15.0 to 19.9 ng/mL (47.7 to 63.3 nmol/L), P missed 5.3% of the EPs and incorrectly included 84.3% of the viable IUPs; in the interval of 20.0 to 24.9 ng/mL (63.6 to 79.2 nmol/L), sensitivity improved in that only 3.5% of the EPs were missed but 88.8% of viable IUPs were included incorrectly. A cutoff value of > or = 17.5 ng/mL (55.7 nmol/L), the median point of the 15.0 to 19.9 ng/mL (47.7 to 63.3 nmol/L) interval, missed only 35 of 423 (8.3%) total EPs in the study.

Conclusion: Analysis of ROC curves demonstrates that single serum P has high diagnostic accuracy for differentiating accidents of pregnancy (SAB and EP) from viable IUP, both individually (SAB versus IUP and EP versus IUP) and collectively (SAB + EP versus IUP); it cannot efficiently discriminate SAB versus EP. We conclude that for P > or = 17.5 ng/mL (55.7 nmol/L), patients thought to be at risk for EP may be followed reasonably without ultrasound or further invasive diagnostic studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0015-0282(16)58560-4DOI Listing

Publication Analysis

Top Keywords

versus iup
24
sab versus
24
diagnostic accuracy
20
sab
9
single serum
8
ectopic pregnancy
8
iup
8
roc curves
8
versus
8
+/- 04%
8

Similar Publications

Background: Ectopic pregnancy (EP), one of the most common gynecological emergencies, is the major cause of maternal death in the first trimester and increases the incidence of infertility and repeat ectopic pregnancy (REP). The aim of this study was to compare the effects of different treatment methods for tubal EP on natural pregnancy outcomes.

Methods: We systematically searched PubMed, Embase, Cochrane Library, Web of Science, and Clinical Trials for observational studies on EP (published until October 30,2022 in English) comparing methotrexate (MTX) versus surgery, MTX versus salpingostomy, MTX versus salpingectomy, salpingostomy versus salpingectomy, and MTX versus expectant treatment.

View Article and Find Full Text PDF

Reusable and Disposable Incontinence Underpads: Environmental Footprints as a Route for Decision Making to Decarbonize Health Care.

J Nurs Care Qual

May 2023

Environmental Clarity, Inc, Raleigh, North Carolina (Dr Griffing); and Environmental Genome Initiative, Raleigh, North Carolina (Dr Overcash).

Background: Objectives of quality principles in the clinical setting present nursing with opportunities for quality patient care but at lower environmental footprint. This affects patients, hospital personnel, and community because choices reduce climate change and thus support an innovative nursing role.

Purpose: This article aims to support nursing knowledge to include environment in decisions regarding patient care and reusable versus disposable incontinence underpads (IUPs).

View Article and Find Full Text PDF

The main objective of this study is the evaluation of the accuracy and reliability of a handheld point of care ultrasound device (POCUS-hd) for intrauterine pregnancy (IUP) detection compared to comprehensive reference transabdominal ultrasound (TU). The secondary objectives were to evaluate POCUS-hd for intrauterine pregnancy (IUP) detection compared to transabdominal and transvaginal ultrasound (TUTV), evaluate the inter-device agreement and inter-rater reliability of gestational age during early pregnancy. It is an observational transverse study with consecutive patient recruitment.

View Article and Find Full Text PDF

Tubal ectopic pregnancy: a retrospective cohort study on clinical characteristics, treatment options and reproductive outcomes within 5 years.

Arch Gynecol Obstet

December 2022

Shanghai First Maternity and Infant Hospital, School of Medicine, Tongji University, Shanghai, 200092, People's Republic of China.

Purpose: To investigate the association between different treatments of tubal ectopic pregnancy (EP) -expectant management, methotrexate (MTX), selected or recommended laparoscopic surgery-and the subsequent reproductive outcomes.

Methods: We conducted a retrospective cohort study including 228 EPs. The patients were divided into four treatment groups: 28 (12.

View Article and Find Full Text PDF

The use of fresh compared to frozen ejaculated sperm has no impact on fresh embryo transfer cycle reproductive outcomes.

J Assist Reprod Genet

June 2022

Division of Urology, Weill Cornell Medicine, 525 E 68th St, Starr 900, New York, NY, 10065, USA.

Purpose: To compare the reproductive outcomes of fresh embryo transfer (ET) cycles utilizing fresh versus frozen ejaculated sperm.

Methods: First autologous fresh embryo transfer cycles at a single high-volume academic institution between 2013 and 2019 were retrospectively reviewed. IVF cycles using ejaculated sperm were included, and cycles using donor or surgically retrieved sperm were excluded.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!