Dental impressions can increase the transmission of microorganisms and infections. The purpose of this study was to assess the influence of three disinfectant solutions on the dimensional accuracy of seven elastomeric impression materials. Impressions of a test block were either left untreated (controls) or treated by immersion in a disinfectant solution. Measurements were taken on die stone replicas of the impressions. Comparisons were made between (1) the measurements for the variations in the nontreated impressions and those for the treated impressions and (2) measurements for the treated impressions and the test block. Results indicated that the aminoamphoteric agent or glutaraldehyde derivative-based solutions created little change in relation to the initial dimensional accuracy of the impression products. However, the sodium hypochlorite solution often leads to expansion by comparison with controls. By comparison to the test block, this expansion then makes it possible in most cases to obtain better dimensional accuracy than initially. Within the limits of this study this expansion could lead to an improvement in clinical fixed prosthodontic procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0022-3913(96)90338-8DOI Listing

Publication Analysis

Top Keywords

dimensional accuracy
12
test block
12
elastomeric impression
8
impression materials
8
impressions test
8
treated impressions
8
impressions
6
dimensional
4
dimensional stability
4
stability elastomeric
4

Similar Publications

Diagonal loading common spatial patterns with Pearson correlation coefficient based feature selection for efficient motor imagery classification.

Comput Methods Biomech Biomed Engin

January 2025

Department of Electronics and Electrical Communications, Faculty of Electronic Engineering, Menoufia University, Menouf, Egypt.

The conversion of a person's intentions into device commands through the use of brain-computer interface (BCI) is a feasible communication method for individuals with nervous system disorders. While common spatial pattern (CSP) is commonly used for feature extraction in BCIs, it has limitations. It is known for its susceptibility to noise and tendency to overfit.

View Article and Find Full Text PDF

3D scanner's potential as a novel tool for lymphedema measurement in mouse hindlimb models.

Sci Rep

January 2025

Department of Plastic and Reconstructive Surgery, Faculty of Medicine, Hokkaido University, Sapporo, Japan.

Lymphedema is characterized by persistent swelling due to impaired lymphatic function and presents significant challenges in both research and clinical settings. Traditional contact-based measurement techniques such as paw thickness and circumferential measurements using calipers or silk thread are useful but limited by observer variability and measurement accuracy. Non-contact methods, including various imaging techniques, offer improvements but often at higher cost and complexity.

View Article and Find Full Text PDF

Lateral lumbar interbody fusion(LLIF), including extreme lateral interbody fusion(XLIF) and oblique lateral interbody fusion(OLIF), constitute a treatment option for many lumbar disorders that predominantly cause degenerative disc disease. LLIF is beneficial for managing conditions, such as lumbar spondylolisthesis, degenerative disc disease, and adult spinal deformities. LLIF is preferred for enabling indirect decompression of the spinal canal and nerve root foramen, without inducing immediate postoperative damage to the peri-vertebral tissues.

View Article and Find Full Text PDF

Detection and correction of translational motion in SPECT with exponential data consistency conditions.

Phys Med Biol

January 2025

Université de Lyon, CREATIS ; CNRS UMR5220 ; Inserm U1206 ; INSA-Lyon ; Université Lyon 1, CREATIS, Centre Léon Bérard, Lyon, 69373, FRANCE.

Rigid patient motion can cause artifacts in single photon emission computed tomography (SPECT) images, compromising the diagnosis and treatment planning. Exponential data consistency conditions (eDCCs) are mathematical equations describing the redundancy of exponential SPECT measurements. It has been recently shown that eDCCs can be used to detect patient motion in SPECT projections.

View Article and Find Full Text PDF

A comparative analysis of CNNs and LSTMs for ECG-based diagnosis of arrythmia and congestive heart failure.

Comput Methods Biomech Biomed Engin

January 2025

Centre for Research Impact & Outcome, Chitkara University Institute of Engineering and Technology, Chitkara University, Rajpura, Punjab, India.

Cardiac arrhythmias are major global health concern and their early detection is critical for diagnosis. This study comprehensively evaluates the effectiveness of CNNs and LSTMs for the classification of cardiac arrhythmias, considering three PhysioNet datasets. ECG records are segmented to accommodate around ∼10s of ECG data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!