Shear bond strength and failure location were used to evaluate the effectiveness of plastic bracket primers for bonding diacrylate adhesives on a new fibre-reinforced polycarbonate bracket. Maxillary incisor polycarbonate and mesh-based brackets as control were bonded to human incisors with 14 different adhesives (four filled diacrylate two-paste, six diacrylate one-step and four power-liquid acrylic adhesives), and after thermo-cycling for 2000 cycles between 5 degrees and 55 degrees C, tested in shear. A non-parametric test (Mann-Whitney U test) was used to compare the shear bond strength of the polycarbonate brackets with the mesh based brackets and a One-way test (according to Scheffe) to compare the shear bond strength of different adhesives. The following conclusions can be made: 1. Seven of the 14 adhesives used in this study with both types of brackets demonstrated adequate shear bond strength values for the clinical application. The exceptions were: Achieve Mix, No-Mix:30 Silkon, Lee Insta-Bond, Ortho-Loc and Bond-Eze, all with too low a shear bond strength for one or both types of brackets, and finally Quasar, which used with the plastic brackets sometimes caused enamel fractures, due to high bond strength. 2. The adhesives with their own plastic primer demonstrated higher blood strength values than those without plastic primer, and two-paste adhesives used with plastic primer displayed a higher bond strength than the other adhesives. 3. Generally, the shear bond strength values of the one-step adhesives were lower compared with the two-paste adhesives. 4. The liquid-powder adhesives demonstrated very different values for bond strength.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ejo/18.3.295 | DOI Listing |
J Prosthet Dent
January 2025
Associate Professor, Department of Prosthodontics, Dental Branch, Islamic Azad University of Medical Sciences, Tehran, Iran.
Statement Of Problem: The optimal zirconia pretreatment, contingent upon the type of cement used, warrants further research.
Purpose: The purpose of this investigation was to evaluate the influence of various surface pretreatments on the bonding efficacy of cement to zirconia.
Material And Methods: A comprehensive search was conducted across the PubMed, Embase, Scopus, and Web of Science databases for in vitro studies related to bonding with zirconia up to April 2024, supplemented by a manual search.
Braz Oral Res
January 2025
Universidade de São Paulo - USP, School of Dentistry, Department of Operative Dentistry, São Paulo, SP, Brazil.
The aim of this study was to assess the effect of a chlorhexidine digluconate solution (CHX) applied as an antiproteolytic agent for controlling erosive tooth wear or as part of the adhesive treatment on long-term bond strength to eroded dentin. Dentin specimens were abraded with a 600-grit silicon carbide (SiC) paper for 1 min (sound dentin - S), subsequently treated with 2% CHX for 1 min (with excess removed, followed by a 6-hour rest), and eroded by exposure to Coca-Cola for 5 min, three times a day, for 5 days (CHX-treated and eroded dentin - CHXE), or only eroded (eroded dentin - E). The specimens were acid-etched (15 s), rinsed (30 s), dried (15 s), and rehydrated with 1.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Conservative Dentistry Department, Faculty of Oral and Dental Medicine, Future University, Cairo, Egypt.
Background: This study aimed to assess the influence of different pretreatment protocols and antioxidants application on the shear bond strength (SBS) of universal adhesive to sound (SoD) and caries-induced dentin (CID).
Methods: One hundred and twenty posterior teeth had their occlusal enamel removed, then the specimens were divided into two main groups according to dentin substrates; SoD and CID, three subgroups according to pretreatments protocols control (no pretreatment), NaOCl-treated, and Er, Cr:YSGG-treated and two divisions according to antioxidant application (with and without sodium ascorbate (SA) application). All-Bond Universal (ABU) universal adhesives was applied in self-etch (SE) mode then resin composite discs were built.
Environ Sci Technol
January 2025
State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, PR China.
Cadmium (Cd) isotopes have recently emerged as novel tracers of Cd sources and geochemical processes. Widespread clay minerals play a key role in Cd migration due to their strong adsorption capacity, but the mechanism of Cd isotope fractionation during adsorption onto clay minerals is poorly understood. Here, we experimentally investigated the adsorption mechanisms of Cd on montmorillonite (2:1) and kaolinite (1:1) by using extended X-ray absorption fine structure (EXAFS) spectroscopy.
View Article and Find Full Text PDFSci Rep
January 2025
State Key Laboratory of Structure Analysis, Optimization and CAE Software for Industrial Equipment, Department of Engineering Mechanics, Dalian University of Technology, Dalian, 116024, China.
The biocompatible autonomous self-healing hydrogels have great potential in biomedical applications. However, the fairly weak tensile strength of the hydrogels seriously hinders their application. Here, we introduced chitosan (CS) into the polyvinyl alcohol (PVA)-tannic acid (TA) hydrogel and investigated the effects of the CS content, as CS can not only form reversible H bonds with PVA and TA but also form reversible electrostatic interactions with TA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!