Recently, two methods have been proposed for regional cerebral blood flow (rCBF) quantitation using [123I]iodoamphetamine (IMP) and single-photon emission computed tomography (SPECT). The table look-up (TLU) method has been shown to provide both rCBF and volume of distribution, Vd, images from two SPECT scans, while a single-scan autoradiographic (ARG) technique provided rCBF using a fixed and assumed Vd. In both methods, a single blood sample was referred to calibrate the previously determined standard input function. The present multicenter project was designed to evaluate the accuracy of both methods for use as clinical investigative tools. Ten independent institutions performed [123I]IMP-SPECT studies according to both methods in 76 subjects (10 normal volunteers, 32 patients with cerebrovascular disease, and 34 patients with other diseases). Calculated rCBF values were compared with those obtained by the following reference methods available in the participating institutions; [15O] H2O positron emission tomography (PET) (five institutions), [133Xe]SPECT (four institutions), and the [123I]IMP microsphere method (three institutions). Both ARG and TLU methods provided rCBF values that were significantly correlated with those measured by the [15O] H2O PET technique (p < 0.001 for all subjects; overall regression equation, y = 15.14 + 0.54x) and those measured by the [123I]IMP-microsphere method (p < 0.001 for all subjects: y = 2.0 + 0.80x). Significant correlation (p < 0.05) was observed in 18 of 24 subjects studied with the [133Xe] SPECT reference technique (overall regression equation, y = 15.0 + 0.55x). Mean cortical gray matter rCBF in a group of normal subject was 43.9 +/- 3.3 and 43.4 +/- 2.0 ml/min/100 g for the ARG and TLU methods, respectively. Regional Vd of [123I]IMP estimated by the TLU method was 45 ml/ml +/- 20% in the normal cortical region. Close agreement between ARG and TLU rCBF values was observed (y = -3.21 + 1.07x, r = 0.97), confirming the validity of assuming a fixed Vd in the ARG method. Results of this study demonstrate that both the ARG and TLU methods accurately and reliably estimate rCBF in a variety of clinical settings.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004647-199609000-00003DOI Listing

Publication Analysis

Top Keywords

arg tlu
16
rcbf values
12
tlu methods
12
regional cerebral
8
cerebral blood
8
blood flow
8
quantitation [123i]iodoamphetamine
8
emission computed
8
computed tomography
8
methods
8

Similar Publications

Because there are great demands of distinguishing multiple chemically similar analytes, chemical sensors for multivariate analyses have been developed rapidly in the past few decades. However, designing luminescent discriminative sensors based on a monosystem has been a challenge until now. In this work, we first develop a triemitting luminescent discriminative platform named with three different emission centers: blue-emitting center (BDC-NH), green-emitting (Tb@BDC-SO), and red-emitting center (rhodamine B, RhB).

View Article and Find Full Text PDF

Regional differences in distribution volume of I-123 IMP in the human brain: effect on CBF calculated by ARG method.

Ann Nucl Med

July 2002

Department of Nuclear Medicine and Radiology, Institute of Development, Aging and Cancer, Tohoku University, Sendai, Japan.

Objective: Two methods of quantitating cerebral blood flow (CBF) with iodine-123-labeled N-isopropyl-p-iodoamphetamine (I-123 IMP) and a two-compartment model had been proposed; one is the table look-up (TLU) method and the other is the autoradiographic (ARG) method. The TLU method provides values of the cerebral blood flow (CBF) values and distribution volume of I-123 IMP (Vd) independently. In the ARG method, a fixed Vd is applied for the entire brain to calculate CBF.

View Article and Find Full Text PDF

Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (Vd) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP (123I-IMP) single photon emission computed tomography (SPECT).

View Article and Find Full Text PDF

Recently, two methods have been proposed for regional cerebral blood flow (rCBF) quantitation using [123I]iodoamphetamine (IMP) and single-photon emission computed tomography (SPECT). The table look-up (TLU) method has been shown to provide both rCBF and volume of distribution, Vd, images from two SPECT scans, while a single-scan autoradiographic (ARG) technique provided rCBF using a fixed and assumed Vd. In both methods, a single blood sample was referred to calibrate the previously determined standard input function.

View Article and Find Full Text PDF

N-isopropyl-p-[123I]iodoamphetamine (IMP) has been commonly used as a cerebral blood flow tracer, but, significant clearance of IMP from the brain to the blood causes underestimation of cerebral blood flow (CBF) as compared with true CBF when the conventional microsphere model method is applied. Previously, we reported an "Autoradiography method" (ARG method) for measuring CBF by using IMP in which this clearance effect was corrected. This method was based on a two-compartment model (influx: K1, efflux: k2, K1/k2 = distribution volume of IMP (Vd)), the K1 (corresponding to CBF) being obtained form the table which showed a correlation between CBF and the brain counts of SPECT scan with a constant Vd value.

View Article and Find Full Text PDF