The most sensitive analytical techniques available today for detecting immuno assay complexes are radio or enzyme immuno analytical techniques, by which quantities of 10(7)-10(8) analyte molecules can be detected. With the introduction of scanning force microscopy, a new method for detecting biological processes became available. Here, we examine the feasibility of using scanning force microscopy as a biosensitive tool. We demonstrate that single or multiple rabbit anti-human serum albumin molecules form complexes with preadsorbed single human serum albumin molecules on mica. However, no interaction is observed between human immunoglobulin G molecules and preadsorbed single albumin molecules; only separate antigens and antibodies are observed at random positions on the mica. This shows the ability of scanning force microscopy to act as a biosensor for detection of immunocomplexes, and to act as a very powerful tool to study molecule-surface interactions in general.
Download full-text PDF |
Source |
---|
Microbiol Spectr
January 2025
Center for Infectious Diseases, Lab of Infectious Diseases, Leiden University Medical Center, Leiden, the Netherlands.
Unlabelled: Due to increasing antimicrobial resistance and side effects caused by current standard antimicrobial regimens used for treatment of prosthetic joint infection (PJI), alternative options are urgently needed. We aimed to investigate the effect of clindamycin in different exposure strategies against in an mature biofilm model. In short, 7-day biofilms were generated on polystyrene plates and titanium-aluminum-vanadium discs using a clinical PJI isolate.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, Junia-ISEN, UMR 8520-IEMN, F-59000 Lille, France.
The effect of growth temperature and subsequent annealing on the epitaxy of both single- and few-layer TaSe on Se-terminated GaP(111) substrates is investigated. The selective growth of the 1T and 1H phases is shown up to 1 ML according to X-ray and ultraviolet photoelectron spectroscopies. The 1H monolayer, favored at low temperatures, exhibits a very homogeneous coverage after annealing, while the 1T ML, grown at high temperatures, is characterized by a better in-plane orientation.
View Article and Find Full Text PDFJ Am Chem Soc
January 2025
Nanotech@surfaces Laboratory, Empa - Swiss Federal Laboratories for Materials Science and Technology, 8600 Dübendorf, Switzerland.
Polyacene analogues, consisting of short acene segments separated by nonbenzenoid rings, offer intriguing electronic properties and magnetic interactions. Pentalene-bridged polyacenes (PPs), in particular, hold promise for enhancing the electrical conductivity and potential open-shell ground states. However, PPs have remained elusive in solution chemistry due to poor solubility and limited synthetic protocols.
View Article and Find Full Text PDFSci Rep
January 2025
Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
This study aimed to compare the bonding efficacy three bioactive self-adhesive restorative systems to dentin. A total of 80 permanent human molars were utilized in this study. The occlusal enamel was removed to exposed mid-coronal dentin; 40 molars were used for microshear bond strength testing, while the remaining molars were used for micromorphological analysis of restoration/dentin interface.
View Article and Find Full Text PDFJ Endod
January 2025
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China; Department of Cariology and Endodontics, School and Hospital of Stomatology, Wuhan University, Wuhan, China. Electronic address:
Introduction: Fiber posts present significant challenges for nonsurgical endodontic retreatment, as improper removal may result in iatrogenic root perforation or even root fracture. Recently, robotic technology has attracted considerable attention in dentistry and active dental robotic (ADR) systems can perform procedures based on preset instructions, minimizing reliance on the dentist's experience. This case report describes the application of an ADR system for fiber post removal through an existing zirconia crown.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!