To determine whether common carotid artery blood flow measured with an ultrasonic flow transducer would predict brain blood flow in fetal sheep, we measured unilateral common carotid artery blood flow and compared this to simultaneous measurements of total brain blood flows made by radioisotope-labelled microsphere techniques. We studied anaesthetized, exteriorized fetal sheep with intact umbilical circulation after ligation of extracranial, extracerebral arteries and placement of a common carotid artery flow transducer; five fetuses at 120 d gestation had 19 total comparison measurements. As measured by microsphere technique, mean basal blood flow during undisturbed conditions to regional brain areas were similar to normal values reported for the exteriorized ovine fetus; these flows were highly correlated to fetal PaCO2 and successfully varied over a wide range (total brain 9.1-200.4 ml/min/100g and total cortex 6.1-153.1 ml/min/100g) in subsequent experimental conditions of hypercapnia or occluded blood flow. Blood flow as measured by flow transducer significantly correlated (P < or = 0.01) with microsphere measurements of blood flow to total brain (r = 0.56) and total cortex (r = 0.62); regional flow to cerebellum (r = 0.70) and thalamus (r = 0.60) also correlated to transducer measurements. Stronger correlations were observed at low-flow conditions to total brain (r = 0.83) and to total cortex (r = 0.90). As measured by microsphere technique, right and left cortical blood flows were highly correlated (P = 0.0001, r = 0.97), indicating that the flow transducer or surgical manipulation did not disturb the distribution of cerebral blood flow. The mean values for zero flow reference of the transducer were < 1.5% of mean basal flow values. It is concluded that the common carotid artery flow transducer technique developed in this study provides an accurate prediction of blood flow to total brain and total cortex over a wide range of values in fetal sheep. This technique provides a methodologic advantage to sequential experimental interventions and may prove advantageous to studies of fetal sheep cerebral circulation.

Download full-text PDF

Source
http://dx.doi.org/10.1071/rd9960157DOI Listing

Publication Analysis

Top Keywords

blood flow
40
flow transducer
24
carotid artery
20
total brain
20
flow
19
common carotid
16
fetal sheep
16
total cortex
16
blood
12
total
10

Similar Publications

Background And Objectives: Cerebrovascular reactivity (CVR) represents the ability of cerebral blood vessels to regulate blood flow in response to vasoactive stimuli and is related to cognition in cerebrovascular and neurodegenerative conditions. However, few studies have examined CVR in the medial temporal lobe, known to be affected early in Alzheimer disease and to influence memory function. We aimed to examine whether medial temporal CVR is associated with memory function in older adults with and without mild cognitive impairment (MCI).

View Article and Find Full Text PDF

Resistant hypertension is defined as office blood pressure >140/90 mm Hg with a mean 24-hour ambulatory blood pressure of >130/80 mm Hg in patients who are compliant with 3 or more antihypertensive medications. Those who persistently fail pharmaceutical therapy may benefit from interventional treatment, such as renal denervation. Sympathetic nervous activity in the kidney is a known contributor to increased blood pressure because it results in efferent and afferent arteriole vasoconstriction, reduced renal blood flow, increased sodium and water reabsorption, and the release of renin.

View Article and Find Full Text PDF

The current investigation explores tri-hybrid mediated blood flow through a ciliary annular model, designed to emulate an endoscopic environment. The human circulatory system, driven by the metachronal ciliary waves, is examined in this study to understand how ternary nanoparticles influence wave-like flow dynamics in the presence of interfacial nanolayers. We also analyze the effect of an induced magnetic field on Ag-Cu-/blood flow within the annulus, focusing on thermal radiation, heat sources, buoyancy forces and ciliary motion.

View Article and Find Full Text PDF

Deconditioning in quiescent Crohn's Disease patients with heightened fatigue perception.

J Crohns Colitis

January 2025

Professor of Gastroenterology, Translational Medical Sciences, School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham; NIHR Nottingham Biomedical Research Centre, Nottingham.

Background & Objective: IBD fatigue aetiology is poorly understood. This study quantified body composition and physical function alongside proton magnetic resonance imaging (1H MRI) and spectroscopy (31P MRS) measures of organ structure and function in quiescent Crohn's Disease patients (CD) and healthy volunteers (HV), to identify a physiological basis for IBD fatigue.

Methods: Body composition was determined using DEXA and 1H MRI.

View Article and Find Full Text PDF

Background: While most thyroid nodules are benign, 7-15% are malignant. Patients with indeterminate thyroid nodules (specifically Bethesda IV/Thy3f) often undergo diagnostic hemithyroidectomy to reach a diagnosis on final histology. The aim of this study was to assess the feasibility of circulating large extracellular vesicles as diagnostic biomarkers in patients presenting with Thy3f thyroid nodules.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!