A bound on the energy resolution required for quantitative SPECT.

Med Phys

Department of Electrical Engineering and Computer Science, University of California, Berkeley 94720, USA.

Published: January 1996

Scattered radiation is one of several physical perturbations that limit the accuracy of quantitative measurements in single-photon emission computed tomography (SPECT). Improvement in detector energy resolution leads to a reduction of scatter counts and a corresponding improvement in the quantitative accuracy of the SPECT measurement. In this study, simulated SPECT projections of a simple myocardial perfusion phantom were used to investigate the effect of detector energy resolution on the data. The phantom consists of a spherical shell of radionuclide within a 15 cm radius water-filled cylinder. Each projection contains on the order of 3 x 10(5) counts. The results demonstrate that a full-width, half-maximum energy resolution of 3-4 keV is sufficient to render the error due to scatter insignificant compared to the uncertainty due to photon statistics in this case. Further simulations verify that because smaller objects produce less scatter, they can be imaged accurately with degraded energy resolution. These results are useful when designing prototype systems that utilize solid-state detectors and low-noise electronics to achieve improved energy resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.597697DOI Listing

Publication Analysis

Top Keywords

energy resolution
24
detector energy
8
resolution
6
energy
5
bound energy
4
resolution required
4
required quantitative
4
spect
4
quantitative spect
4
spect scattered
4

Similar Publications

The study of transient and variable events, including novae, active galactic nuclei, and black hole binaries, has historically been a fruitful path for elucidating the evolutionary mechanisms of our universe. The study of such events in the millimeter and submillimeter is, however, still in its infancy. Submillimeter observations probe a variety of materials, such as optically thick dust, which are hard to study in other wavelengths.

View Article and Find Full Text PDF

This experimental phantom study investigates current standard of care protocols in cone beam computed tomography (CBCT), energy-integrating-detector (EID) CT, and photon-counting-detector (PCD) CT regarding their potential in delineation of dental root canals. Artificial accessory canals (diameters: 1000, 600, 400, 300 and 200 μm) were drilled into three bovine teeth mounted on a bovine rib as a jaw substitute. The phantom was scanned in two dental CBCTs, two EID-CTs and a PCD-CT using standard clinical protocols.

View Article and Find Full Text PDF

Molecular glue for phycobilisome attachment to photosystem II in sp. PCC 7002.

Proc Natl Acad Sci U S A

January 2025

State Key Laboratory of Protein and Plant Genetic Engineering, School of Life Science, Peking University, Beijing 100871, People's Republic of China.

Phycobilisomes (PBS) are the major photosynthetic light-harvesting complexes in cyanobacteria and red algae. While the structures of PBS have been determined in atomic resolutions, how PBS are attached to the reaction centers of photosystems remains less clear. Here, we report that a linker protein (LcpA) is required for the attachment of PBS to photosystem II (PSII) in the cyanobacterium sp.

View Article and Find Full Text PDF

We demonstrate a high-performance ultrafast broadband time-resolved photoluminescence (TRPL) system based on the transient grating photoluminescence spectroscopy (TGPLS) technique. The core of the system is a Kerr effect-induced transient grating (TG) optical gate driven by high repetition rate ultrashort laser pulses at 1030 nm with micro-Joule pulse energy. Satisfying the demands of spectroscopy applications, the setup achieves high sensitivity, rapid data acquisition, ultrafast time resolution, and a wide spectral window from ultraviolet to near-infrared.

View Article and Find Full Text PDF

Centimeter-Sized CsPbBr Single-Crystal Films for Energy-Resolved Radiation Detection.

ACS Appl Mater Interfaces

January 2025

Beijing Key Laboratory of Construction-Tailorable Advanced Functional Materials and Green Applications Experimental Center of Advanced Materials, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China.

Metal halide perovskites (MHPs) are promising materials for radiation detection. Compared with polycrystalline films, single crystals (SCs) have lower defect density, higher carrier mobility, and lifetime. However, the direct synthesis of MHP SCs for large-area flat panel imaging detectors remains challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!