A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of low-frequency respiratory impedance in infants. | LitMetric

Low-frequency respiratory impedance (Zrs) data permit the separate estimation of the mechanical properties of the airways and the tissues, but they are difficult to collect in humans because of the need for apneic conditions. We exploited the apneic phase produced by invoking the Hering-Breuer reflex with end-inspiratory airway occlusion in five sedated infants aged 9 to 16 mo. A computer-controlled pump and solenoid valves were used to inflate the supine infants through a face mask to a transrespiratory pressure of 20 cm H2O and to affect the airway occlusion. A loudspeaker-in-box system was connected to the mask through a side-arm, and small-amplitude pseudorandom oscillations containing 23 frequency components between 0.5 and 20.75 Hz were applied for 6 s. Four consecutive measurements were made in each infant, and the averaged Zrs spectra were evaluated on the basis of a model containing the frequency-independent resistance (Raw) and inertance (law) of the airways, and the viscous damping (G) and elastance (H) parameters of the constant-phase compartment of the chest wall and parenchymal tissues. The measured Zrs values were consistent with the model up to 15 Hz, and the average fitting error was 0.89 +/- 0.11 (SD) cm H2O.s/L. The following parameter values were obtained: Raw = 10.0 +/- 2.1 cm H2O.s/L, law = 0.061 +/- 0.014 cm H2O.s2/L, G = 28.6 +/- 4.9 cm H2O/L, H = 141 +/- 55 cm H2O/L. The tissue hysteresivity (G/H) values were 0.218 +/- 0.061. Our results indicate that, in short apneic periods evoked by the Hering-Breuer reflex, reliable low-frequency Zrs data can be collected to partition the tissue and airway impedances in sedated infants.

Download full-text PDF

Source
http://dx.doi.org/10.1164/ajrccm.154.1.8680673DOI Listing

Publication Analysis

Top Keywords

low-frequency respiratory
8
respiratory impedance
8
zrs data
8
hering-breuer reflex
8
airway occlusion
8
sedated infants
8
+/- h2o/l
8
+/-
6
measurement low-frequency
4
infants
4