The heterogeneity of schizotypal traits, suggested in previous research, was further investigated in a sample of subjects (N = 1095) administered a composite questionnaire consisting of a large number of published scales the majority of which were designed to measure psychotic characteristics. Factor analysis confirmed the four components previously indicated in our work with the same instrument; namely, "aberrant perceptions and beliefs', "cognitive disorganization', "introvertive anhedonia' and "asocial behaviour'. This structure was maintained regardless of whether or not the analysis included scales from the Eysenck Personality Questionnaire, which might otherwise have been held to explain the variance. "Aberrant perceptions and beliefs'-reminiscent of the positive symptoms of schizophrenia-was the strongest component; but, given the multidimensional nature of the data, together with the pattern of factor loadings and intercorrelations for the scales involved, it was concluded that the broader term "psychosis-proneness' or "psychoticism' (in a non-Eysenckian sense) might be a better descriptor of the clinical and personality domain sampled.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.2044-8260.1996.tb01166.xDOI Listing

Publication Analysis

Top Keywords

"aberrant perceptions
8
factor structure
4
structure "schizotypal'
4
"schizotypal' traits
4
traits large
4
large replication
4
replication study
4
study heterogeneity
4
heterogeneity schizotypal
4
schizotypal traits
4

Similar Publications

Effects of effective optical zone and decentration on visual quality after smile for different astigmatism types.

BMC Ophthalmol

March 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-sen University, Guangzhou, 510060, China.

Purpose: To compare the refractive outcomes and visual quality among different types of astigmatism following SMILE and evaluate effective optical zone (EOZ) features, decentration and their potential effects on visual quality.

Methods: This study included 101 left eyes of 101 patients who underwent SMILE. Patients were grouped according to astigmatism types (with-the-rule [WTR], against-the-rule [ATR] and oblique astigmatism) and decentered displacement (major axis > minor axis and major axis < minor axis).

View Article and Find Full Text PDF

Purpose: To evaluate the efficacy, predictability, and safety of laser in situ keratomileusis (LASIK) for the correction of myopia and myopic astigmatism using the SCHWIND Amaris 1050RS excimer laser (SCHWIND eye-tech-solutions).

Methods: This was a prospective cohort study of 1,420 eyes with myopia or myopic astigmatism that underwent LASIK in a single tertiary center between January 2017 and April 2022. The IntraLase iFS femtosecond laser (Johnson & Johnson Vision) was used for flap creation and excimer laser ablation was performed using the SCHWIND Amaris 1050RS with aspheric aberration-free ablation profile, asymmetric pupillary offset, and seven-dimensional eye tracking.

View Article and Find Full Text PDF

Purpose: To evaluate and compare non-corneal intraocular higher order aberrations (HOAs) in keratoconic and normal myopic eyes.

Methods: Eighty-eight keratoconic and 106 normal myopic eyes were examined using high-resolution (1) pyramidal ocular wavefront sensor PERAMIS (designed by CSO for SCHWIND eye-tech-solutions GmbH) and (2) anterior segment optical coherence tomography (AS-OCT) MS-39 (CSO). Intraocular HOAs were calculated by subtracting the total corneal aberrations measured by the AS-OCT from the total ocular aberrations measured by the pyramidal aberrometer.

View Article and Find Full Text PDF

Purpose: To evaluate and compare the effect of pupil size, spherical aberration (SA), decentration, and tilt on the optical performance of five different monofocal intraocular lenses (IOLs).

Methods: Four aspheric IOLs (Vivinex, Hoya; SN60WF, Alcon Laboratories, Inc; ZCB00, Johnson & Johnson Surgical Vision; Akreos Adapt AO, Bausch & Lomb) with different SA values and one spherical IOL (SN60AT, Alcon Laboratories, Inc) were tested using an OptiSpheric IOL PRO 2 optical bench. The IOL diopter was measured at different apertures.

View Article and Find Full Text PDF

Purpose: To investigate how varying levels of longitudinal chromatic aberration (LCA) affect visual quality in patients with trifocal intraocular lenses (IOLs).

Methods: Twenty-nine patients implanted with trifocal IOLs were assessed for corrected distance visual acuity (CDVA), defocus curves, the contrast sensitivity function, and the area under the logarithmic contrast sensitivity function (AULCSF). The measurements were performed under natural viewing conditions after introducing +1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!