AI Article Synopsis

  • The study aimed to define a more accurate level of anaesthesia by examining individual cardiovascular responses to a painful stimulus, acknowledging that patients react differently to anaesthetics.
  • In a group of 61 patients under general anaesthesia, the researchers observed cardiovascular reactions to varying concentrations of isoflurane, noting the concentration needed to avoid significant reactions.
  • Results showed that EEG readings correlated with the cardiovascular reactions, indicating that individualized measurements of anaesthetic depth can lead to more consistent EEG patterns, enhancing the relationship between EEG and anaesthesia depth.

Article Abstract

Aim: Previous studies using EEG for assessment of depth of anaesthesia correlate anaesthetic concentration with the anaesthetic stage. This procedure neglects the well known effect of individual different susceptibility to anaesthetics. Thus, patients receiving similar concentrations of anaesthetics may not necessarily be at the same level of "anaesthetic depth". The aim of this study was to define an interindividual comparable level of anaesthesia by recording the autonomic cardiovascular reaction to a standardised painful stimulus (tetanic stimulus, 80 mA, 100 Hz).

Methods: In 61 patients undergoing orthopaedic surgery general anaesthesia was performed with isoflurane in 66% N2O. Starting from 0.4% isoflurane, endtidal isoflurane concentration was increased in a stepwise manner (0.1% isoflurane) until the patient did not show any relevant cardiovascular reaction (increase of heart rate and/or blood pressure < 10%) after tetanic stimulation of the ulnar nerve. If patients demonstrated no haemodynamic changes at 0.4% isoflurane, the concentration was decreased until a relevant cardiovascular reaction was registered. During each steady state period multichannel EEG was recorded and mean values of power density (median: microV2/Hz) were computed.

Results: Comparing EEG-results between both groups exhibiting a cardiovascular reaction (CVR+ , median endtidal Iso: 0.5%) and without reaction (CVR- , median endtidal Iso: 0.6%) an increase in low frequency bands and a significant decrease in high frequencies was found (Wilcoxon-test, p < 0.05). In contrast, comparing EEG-data only in relation to endtidal isoflurane concentration neglecting individual haemodynamic responses, no differences of power density in high frequency bands were detected.

Conclusion: This method to define individual depth of anaesthesia as described, results in more consistent EEG patterns and may be useful in relating EEG to depth of anaesthesia.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2007-995892DOI Listing

Publication Analysis

Top Keywords

cardiovascular reaction
16
depth anaesthesia
12
isoflurane concentration
12
04% isoflurane
8
endtidal isoflurane
8
relevant cardiovascular
8
power density
8
median endtidal
8
endtidal iso
8
frequency bands
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!