Gastric tonometry has been introduced for the early detection of impaired splanchnic perfusion by determination of the intramucosal PCO2. However, due to methodological problems, i.e., instability of CO2 in water, to assess the exact intramucosal PCO2 with the nasogastric tonometer is unreliable. The present in vitro and in vivo study examines a new fiberoptic PCO2 sensor for the continuous determination of the intramucosal PCO2 and compares these data with that of conventional tonometry. In an in vitro experiment the fiberoptic PCO2 sensor was used to determine the PCO2 of water and humidified air with predefined CO2 values. In both media, predefined CO2 values (35, 42, 49 mm Hg) could be assessed exactly after 9 min of equilibration with a maximum deviation less than 3.5%. In contrast, the values obtained by conventional tonometry showed larger differences. In in vivo experiments on six pigs PCO2 differences were induced by ventilatory changes to validate the fiberoptic PCO2 sensor. Under anesthesia a laparotomy was performed, the ileum punctured, and the fiberoptic PCO2 sensor introduced into the ileal lumen. Arterial PCO2 (PaCO2), mesenteric venous PCO2 (PmvCO2), and intramucosal PCO2, (PiCO2) were determined during normoventilation, hypoventilation, and hyperventilation. During hypoventilation the PiCO2 increased from 53.8 +/- 2.0 mm Hg (PaCO2 = 39.8 +/- 1.4 mm Hg, PmvCO2 = 48.7 +/- 2.7 mm Hg) to 66.5 +/- 4.9 mm Hg (PaCO2 = 52.7 +/- 3.1 mm Hg, PmvCO2 = 62.4 +/- 5.7 mm Hg). With hyperventilation the PiCO2 decreased to 46.8 +/- 2.5 mm Hg (PaCO2 = 29.8 +/- 1.8 mm Hg, PmvCO2 = 41.8 +/- 2.7 mm Hg). The coefficient of correlation (r2) between PiCO2 and PaCO2 was 0.82, and between PiCO2 and PmvCO2 0.94. The fiberoptic PCO2 sensor can determine PiCO2 in a precise and reliable manner, and can continuously record fast intraluminar changes of CO2 in the ileum that were caused by ventilatory changes. The fiberoptic PCO2 sensor is the only method that reliably monitors PiCO2 in the gastrointestinal tract. By the direct measurement of PCO2 the methodological problems associated with the conventional nasogastric tonometry are abolished.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00000539-199607000-00003 | DOI Listing |
Tuberk Toraks
December 2020
Department of Chest Diseases, University of Health Sciences, Ankara Diskapi Yildirim Beyazit Research and Training Hospital, Ankara, Turkey.
Introduction: The aim of the study was to assess the effects of interventions during bronchoscopy on ventilation and determine the risk factors for hypoventilation related to both interventions and patients' demographical and clinical characteristics.
Materials And Methods: A total of 74 patients who underwent fiberoptic bronchoscopy (FOB) were included in the study. Oxygen saturation (SpO2) and partial carbon dioxide pressure (PCO2) were measured transcutaneously (TcSO2 and TcPCO2) using a sensor consisting of a probe placed on the earlobe.
Physiol Rep
October 2019
Tactical and En Route Care Department, U.S. Army Institute of Surgical Research, JBSA, Fort Sam Houston, Texas.
Proc Biol Sci
July 2019
Department of Zoology, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z4.
Our goal was to use novel fibreoptic sensors to make the first direct PCO measurements in the digestive tracts of live freshwater fish (anaesthetized, artificially ventilated, 12°C). PCO levels in gastrointestinal fluids were substantially higher than in blood, and were elevated after feeding. In the carnivorous, gastric rainbow trout, the mean PCO in various parts of the tract increased from 7-13 torr (1 torr = 0.
View Article and Find Full Text PDFPediatr Transplant
June 2019
Royal Papworth Hospital, Cambridge, UK.
A clinical case of successful procurement and transplantation of bilateral lungs from 6-week-old infant with sepsis secondary to bacterial meningitis is reported. Forty-one-day-old male infant (height 60 cm, weight 4 kg) died of cerebral edema secondary to Escherichia coli meningitis and bacteremia. Preretrieval assessment included the following: arterial gases; pO 50.
View Article and Find Full Text PDFLung
February 2019
Pulmonary Division, Rabin Medical Center, Petach Tikva, Israel.
Purpose: There is clinical significance to a delay in response time for detecting desaturation by pulse oximetry. Our aim in this study was to compare the response time of the reflectance and transmittance saturation probes during fiberoptic bronchoscopy (FOB) under monitored anesthesia care.
Methods: A prospective study included 104 patients scheduled for FOB.