A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Thermo-mechanical behavior the the cornea]. | LitMetric

Background: Shrinkage of corneal collagen is used during thermokeratoplasty, a method to remodel the corneal curvature. The goals of our investigations were to determine the optimal temperature range for maximal shrinkage of the collagen fibers with minimal damage.

Materials And Methods: By means of a commercially available stress-strain-measuring device with a paraffin oil bath of temperatures varying from 35 degrees C to 120 degrees C strips of pig cornea 5 mm in width and 9 mm in length were investigated in the physiological stress range from sigma = (0,5-12,5) . 10(4) N/m2 by stress-strain, stress relaxation and creep measurements.

Results: Biomechanical properties of the cornea remain unchanged in the temperature range from 30 to 50 degrees C. Starting at 60 degrees C shrinkage occurs that increases up to 90 degrees C. The maximal rate of shrinkage of (57 +/- 12)% was measured at temperatures of 75 to 80 degrees C. Above 100 degrees C this effect is reduced by the destruction of intermolecular bonds between the collagen fibers. The stress-strain curves of the shrunk corneas are flatter than that of native corneas, which means, the Young's modulus is significantly reduced.

Conclusions: In order to realize optimal shrinkage during thermokeratoplasty temperatures of 65-85 degrees C should be achieved in the coagulated tissue. Higher temperatures cause also a shrinkage effect but also a destruction of tissue.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2008-1035180DOI Listing

Publication Analysis

Top Keywords

temperature range
8
collagen fibers
8
degrees
8
shrinkage
6
[thermo-mechanical behavior
4
behavior cornea]
4
cornea] background
4
background shrinkage
4
shrinkage corneal
4
corneal collagen
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!