The value of the RBE of a test radiation is conventionally determined against a known standard radiation for a chosen response of a selected biological tissue and is expressed as the ratio of tissue absorbed doses at equal effect, or as ratio of magnitudes of the effect at equal absorbed dose. If such an effect is observable as a consequence of responses of individual elements of this tissue, namely the cells, such as induction of cancer that arises from a single cell, the relative biological effectiveness should be expressed as the ratio of the incidences of the effects at equal mean absorbed dose to the cells rather than at equal absorbed dose to tissue. This cell based relative biological effectiveness is here termed the relative local efficiency. Since tissue absorbed dose is a product of the number of energy deposition events in cells of that tissue (N(H)) and the mean absorbed dose to these cells in the exposed tissue (z(1)), per tissue mass equal tissue absorbed doses from different radiation qualities have different values of N(H) and z(1) As a result, for pink mutations in Tradescantia cells, the relative biological effectiveness of 0.43 MeV neutrons is 48 but the relative local efficiency in fact is 2.8.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004032-199606000-00011DOI Listing

Publication Analysis

Top Keywords

absorbed dose
20
relative biological
16
biological effectiveness
16
tissue absorbed
16
equal absorbed
12
tissue
11
tissue cells
8
expressed ratio
8
absorbed doses
8
dose cells
8

Similar Publications

The radiation exposure to bystanders from nuclear medicine patients is a common concern raised in nuclear medicine departments. The GATE (Geant4 Application for Tomographic Emission) Monte Carlo radiation transport application was used to estimate the dose to a bystander. Two voxelised phantoms were utilised in a GATE Monte Carlo simulation as the radiation source and target.

View Article and Find Full Text PDF

Background: Oritavancin (ORT) is a new single-dose lipoglycopeptide showing activity against staphylococci and vancomycin-resistant enterococci. However, there is no data regarding its potential use as a catheter lock solution are scarce. We constructed an model to analyze the efficacy and stability of an ORT lock solution against the biofilm of staphylococci and enterococci over 7 days at 37 °C.

View Article and Find Full Text PDF

Optimal timing for lithium levels.

F1000Res

January 2025

Departments of Psychiatry, Neurology, Radiology, and Neuroscience, Washington University in St. Louis School of Medicine, St. Louis, MO, 63110, USA.

Reddy and Reddy (2014) discuss the optimal timing for lithium levels in patients taking once-daily extended-release lithium formulations. They argue for blood sampling 24 h after the previous dose rather than the standard 12 h. I interpret the data quite differently.

View Article and Find Full Text PDF

Toward Developing Alternative Opioid Antagonists for Treating Community Overdose: A Model-Based Evaluation of Important Pharmacological Attributes.

Clin Pharmacol Ther

January 2025

Division of Applied Regulatory Science, Office of Clinical Pharmacology, Office of Translational Sciences, Center for Drug Evaluation and Research, Food & Drug Administration, Silver Spring, Maryland, USA.

In response to increased illicit use of synthetic opioids, various μ-receptor antagonist formulations, with varied pharmacological characteristics, have been and are being developed. To understand how pharmacologic characteristics such as absorption rate and clearance rate affect reversal in treating community opioid overdose, we used our previously published translational opioid model. We adapted this model with in vitro receptor binding data and clinical pharmacokinetic data of three intranasal nalmefene formulations along with an intranasal naloxone formulation to study the reversal of fentanyl and carfentanil-induced respiratory depression in chronic opioid users.

View Article and Find Full Text PDF

Ra, Th, and K levels in various foods frequently consumed by Egyptians were determined using a gamma-ray spectrometer based on the germanium detector (HPGe). Activity concentrations of Ra, Th, and K were in the range of < 0.10 to 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!