[Asthma-like symptoms due to thoracic aneurysm].

Nihon Kyobu Shikkan Gakkai Zasshi

Department of Internal Medicine, Kakegawa Municipal Hospital, Japan.

Published: February 1996

AI Article Synopsis

  • A 77-year-old woman with a history of hypertension experienced severe shortness of breath and chest pain due to an extensive thoracic aneurysm compressing her tracheobronchial tree.
  • She exhibited acute respiratory distress, cyanosis, and abnormal vital signs, leading to a chest X-ray that indicated significant tracheal compression and loss of lung volume.
  • Despite symptom stabilization and no surgery due to her age and aneurysm size, she eventually died from a rupture of the aneurysm.

Article Abstract

We describe a case of positional dyspnea due to compression of the tracheobronchial tree by an extensive thoracic aneurysm. In a 77-year-old woman with long-standing systemic hypertension, intermittent anterior chest pain gradually developed over several years. She had no history of asthma or thoracic trauma. She was admitted to our hospital because of sudden, severe shortness of breath. The breathlessness was markedly worse when she lay on her back or on her right side. On physical examination, she was in acute respiratory distress with cyanosis, severe hypertension (180/110 mmHg), tachycardia, and inspiratory stridor. A chest X-ray film showed loss of volume and nearly complete radiopacity of the left hemithorax. Arterial blood gas analysis revealed an arterial oxygen partial pressure of 54.8 mmHg, a carbon dioxide partial pressure of 39.8 mmHg, and an oxygen saturation of 84.5 percent on room air. Computed tomographic examination of the thorax showed dilation of the aortic arch and descending aorta, and marked compression of the trachea and the left main bronchus. Examination with a fiberoptic bronchoscope revealed extrinsic compression of the trachea just proximal to the carina. The patient's symptoms stabilized. However, she did not undergo surgery because of her age and because of the size of the aneurysm. She died due to rupture of the aneurysm.

Download full-text PDF

Source

Publication Analysis

Top Keywords

partial pressure
8
compression trachea
8
[asthma-like symptoms
4
symptoms thoracic
4
thoracic aneurysm]
4
aneurysm] describe
4
describe case
4
case positional
4
positional dyspnea
4
dyspnea compression
4

Similar Publications

Nasal high flow (NHF) therapy is an established form of non invasive respiratory support used in acute and chronic care. Recently, a new high flow nasal cannula with asymmetric prongs was approved for clinical use. The clinical benefits of the new cannula have not yet been defined and no evidence are available on the use of asymmetric NHF support in patient with Chronic Obstructive Pulmonary Disease (COPD).

View Article and Find Full Text PDF

Accuracy of two-compartment modelling of gas exchange with ventilation-perfusion mismatch in inhalational anesthesia.

Anesthesiology

January 2025

Department of Critical Care, Melbourne Medicine School, Faculty of Medicine, Dentistry and Health Sciences, University of Melbourne, Victoria, Australia.

Background: Multi-compartment computer models of heterogeneity in alveolar ventilation-perfusion ratios (VA/Q scatter) across the lung explain the significant alveolar-arterial (A-a) partial pressure gradients and associated alveolar dead-space fractions (VDA/VA) seen in anesthetized patients for both carbon dioxide and for anesthetic gases of different blood solubilities. However, the accuracy of a simpler two-compartment model of VA/Q scatter to do this has not been tested or compared to calculations from the traditional Riley model with "ideal", unventilated (shunt) and unperfused (deadspace) compartments.

Methods: Measurements of gas partial pressures in inspired and expired gas and arterial and mixed venous blood from 29 patients undergoing inhalational general anesthesia for cardiac surgery was used to compare the accuracy of two simple models of VA/Q scatter and lung gas exchange in predicting measured alveolar and arterial partial pressure differences, and associated alveolar dead-space calculations for the modern anesthetic gases isoflurane, sevoflurane and desflurane.

View Article and Find Full Text PDF

Fiber Sorbents - A Versatile Platform for Sorption-Based Gas Separations.

Acc Mater Res

January 2025

School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia 30322, United States.

Increasing demand for high-purity fine chemicals and a drive for process intensification of large-scale separations have driven significant work on the development of highly engineered porous materials with promise for sorption-based separations. While sorptive separations in porous materials offer energy-efficient alternatives to longstanding thermal-based methods, the particulate nature of many of these sorbents has sometimes limited their large-scale deployment in high-throughput applications such as gas separations, for which the necessary high feed flow rates and gas velocities accrue prohibitive operational costs. These processability limitations have been historically addressed through powder shaping methods aimed at the fabrication of structured sorbent contactors based on pellets, beads or monoliths, commonly obtained as extrudates.

View Article and Find Full Text PDF

Background: To estimate a correlation between change in lung ultrasound aeration score (LUSS) and mortality in patients with ventilator-associated pneumonia.

Materials And Methods: We conducted a prospective observational study in which lung ultrasound, the partial pressure of arterial oxygen to fraction of inspired oxygen ratio (PaO/FiO ratio), and static lung compliance were performed for five consecutive days since the diagnosis of ventilator-associated pneumonia (day 1-5) in a 20-bed multidisciplinary intensive care unit in at a tertiary care academic institute in Northern India. A hundred and seventeen ventilated patients were studied for the first 5 days after ventilator-associated pneumonia (VAP) development.

View Article and Find Full Text PDF

Introduction: Obstructive sleep apnea (OSA) is characterized by repetitive episodes of complete or partial upper airway collapse during sleep. Restless legs syndrome (RLS) is a sleep-related movement disorder characterized by an uncomfortable urge to move the legs, especially during inactivity and evenings. Both OSA and RLS are common with significant overlap: RLS is present in up to 36% of those with OSA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!