Purpose: The clinical usefulness of an advanced image-processing system called "dynamic range control processing" was investigated, with which selected parts of the dynamic range of digital chest images could be controlled.
Material And Methods: A comparative study of 3 different post-processed formats of storage phosphor (SR) images was performed in 35 patients with abnormalities in the chest. The 3 formats were SR images with standard mode (SR-standard), SR images with strong edge-enhancement (SR-enhanced), and dynamic range controlled SR images (SR-controlled).
Results: For lung abnormalities, there was no difference among the 3 SR image formats. For normal mediastinal structures and lung abnormalities covered by the heart or diaphragm, SR-controlled and SR-enhanced images were significantly superior to SR-standard images, while no difference was found between SR-controlled and SR-enhanced images except for the trachea and bony structures.
Conclusion: Dynamic range control processing appears to be a useful method for displaying SR chest images with an extremely wide dynamic range.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/02841851960371P121 | DOI Listing |