Late coronary artery stenosis regression within the Gianturco-Roubin intracoronary stent.

Am J Cardiol

Nasser, Smith & Pinkerton Inc., Indianapolis, Indiana, USA.

Published: February 1996

The late angiographic outcome of the Gianturco-Roubin intracoronary stent has not been well defined. To investigate serial changes within the stent, we studied 23 patients (15 men and 8 women, median age 63) who had late angiographic follow-up ( > 1 year) after undergoing Gianturco-Roubin stenting for angioplasty-associated acute or threatened native coronary artery closure. Coronary angiography before and after stenting, at 6-month follow-up, and at late return was analyzed with quantitative coronary angiography. The median time from stent deployment to late angiographic follow-up was 27 months. As expected, stenting significantly increased the median minimal lumen diameter (MLD) acutely from 1.0 to 2.46 mm. Median percent diameter stenosis decreased from 66% to 18%. Although at 6 months there was a significant loss of the acute gain (median MLD decreased from 2.46 to 1.9 mm), with a corresponding increase in percent stenosis from 18% to 31%, late angiography demonstrated lesion regression, median MLD increasing from 1.9 to 2.15 mm (p = 0.004), and percent stenosis decreasing from 31% to 21% (p = 0.0026). No patient had a significant decline in minimal lesion diameter, and 5 patients had a > 50% increase in MLD at late follow-up. Linear regression analysis of 6-month MLD and late lumen gain suggested that lesions with the greatest regression were those with the lowest lumen diameters at 6-month angiography. Late angiographic analysis demonstrated significant lesion regression within the Gianturco-Roubin stent, which was sometimes dramatic. In suggesting that coronary arteriography at 6 months may underestimate the late angiographic benefit of intracoronary stenting, these data have important clinical implications, and imply that patients with a stable clinical course and angiographic stent restenosis may often be followed rather than routinely redilated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0002-9149(97)89387-3DOI Listing

Publication Analysis

Top Keywords

late angiographic
20
late
10
coronary artery
8
regression gianturco-roubin
8
gianturco-roubin intracoronary
8
intracoronary stent
8
angiographic follow-up
8
coronary angiography
8
median mld
8
percent stenosis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!