Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Pulmonary function may improve after surgical resection of the most severely affected lung tissue (lung-reduction surgery) in patients with diffuse emphysema. The basic mechanisms responsible for the improvement, however, are not known.
Methods: We studied 20 patients with diffuse emphysema before and at least three months after either a unilateral or a bilateral lung-reduction procedure. Clinical benefit was assessed by measurement of the six-minute walking distance and the transitional-dyspnea index, which is a subjective rating of the change from base line in functional impairment and the threshold for effort- and task- dependent dyspnea. Pressure-volume relations in the lungs were measured with static expiratory esophageal-balloon techniques, and right ventricular systolic function was assessed by echocardiography.
Results: The patients had significant improvement in the transitional-dyspnea index after surgery (P<0.001). The mean (+/-SD) coefficient of retraction, an indicator of elastic recoil of the lung, improved (from 1.3+/-0.6 cm of water per liter before surgery to 1.8+/-0.8 after, P<0.001). Sixteen patients with increased elastic recoil had a greater increase in the distance walked in six minutes than the other four patients, in whom recoil did not increase (P=0.02). The improved lung recoil led to disproportionate decreases in residual volume as compared with total lung capacity (16 percent vs. 6 percent), but the decreases in both values were significant (P<0.001). Forced expiratory volume in one second increased (from 0.87+/-0.36 to 1.11+/-0.45 liters, P<0.001). End-expiratory esophageal pressure also decreased (P=0.002). These improvements in lung mechanics led to a decrease in arterial partial pressure of carbon dioxide form 42+/-6 to 38+/-5 mm Hg (P=0.006). Furthermore, the fractional change in right ventricular area, an indicator of systolic function, increased from 0.33+/-0.11 to 0.38+/-0.010 (P=0.02).
Conclusions: Lung-reduction surgery can produce increases in the elastic recoil of the lung in patients with diffuse emphysema, leading to short-term improvement in dyspnea and exercise tolerance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1056/NEJM199604253341704 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!