Background: Analysis of visual disturbances in the central 10 degrees provides valuable data for the low vision clinician. Amsler grid testing in the visually impaired can be poorly visible and it can be difficult to transcribe results. Automated perimeters will accurately map retinal defects, but the equipment is expensive and this technique is time consuming. An Amsler grid was modified using principles of luminance and contrast to improve its accuracy, and its efficacy was compared to an automated perimeter.
Methods: Eighteen visually impaired patients (28 eyes) were prospectively evaluated at the Emory Low Vision Laboratory. Each patient had three central threshold visual field tests: automated perimetry (Humphrey model 690), conventional Amsler Grid, and Illuminated High Contrast Macular Grid (IHCMG). The Humphrey central 10-2 threshold automated visual field examination was performed to map the patient's retinal function.
Results: The Humphrey analysis identified (mean +/- one standard deviation) 2.4 +/- 1.4 defects per patient with an average percent defect area of 33.4 +/- 14.8 degrees. The IHCMG technique was not significantly different from the Humphrey technique for identifying the number of defects (2.25 +/- 1.5) (p > 0.05) or the percent defect area (26 degrees +/- 20 degrees) (p > 0.05). The conventional Amsler grid technique significantly under-evaluated the retinal defects compared to the Humphrey analysis of the number of defects (p < 0.01) and percent area of defects (p > 0.001).
Conclusions: The IHCMG technique can be used as a simple, rapid and accurate analysis of the central 10 degrees visual field in the low vision patient.
Download full-text PDF |
Source |
---|
Int J Ophthalmol
January 2025
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, Zhejiang Province, China.
Improvements in surgical techniques have led to 90% success in the surgical repair of rhegmatogenous retinal detachment (RRD). However, anatomical reattachment of the retina does not ensure complete recovery of visual function. The incidence of metamorphopsia remains the most common postoperative complaint, from 24% to 88.
View Article and Find Full Text PDFSwiss J Geosci
December 2024
Department of Surface Waters Research and Management, Eawag, Überlandstrasse 133, Dübendorf, 8600 Switzerland.
Unlabelled: Industrial activities of a silk dyeing factory in Thalwil, on the shore of Lake Zurich, Switzerland, caused extreme Sn contamination of lake sediments. In this study, we determine the contamination source, spread, and age using a multiproxy approach. We used X-ray fluorescence spectroscopy (XRF) core scanning and further geochemical analyses to assess the contamination spreading and thickness in the sedimentary column.
View Article and Find Full Text PDFInt Ophthalmol Clin
January 2025
Cullen Eye Institute, Baylor College of Medicine, Houston, TX.
Modern treatment protocols for retinal diseases involve frequent in-office monitoring with optical coherence tomography (OCT) and treatment with anti-vascular endothelial growth factor injections. Monthly injections may yield the greatest visual outcomes but are the most burdensome for patients and physicians, while as-needed injections may lead to undertreatment. Hybrid protocols, such as treat-and-extend (TREX) have been conceived to bridge this gap.
View Article and Find Full Text PDFEur Phys J C Part Fields
December 2024
Eur Phys J A Hadron Nucl
November 2024
Stefan Meyer Institute for Subatomic Physics, Austrian Academy of Sciences, Vienna, Austria.
The mechanism of antiproton-nucleus annihilation at rest is not fully understood, despite substantial previous experimental and theoretical work. In this study we used slow extracted antiprotons from the ASACUSA apparatus at CERN to measure the charged particle multiplicities and their energy deposits from antiproton annihilations at rest on three different nuclei: carbon, molybdenum and gold. The results are compared with predictions from different models in the simulation tools Geant4 and FLUKA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!