A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Interscalenic block: accidental catheterization of the epidural space]. | LitMetric

AI Article Synopsis

  • A case study reports the accidental placement of a brachial plexus catheter into the cervical epidural space during an interscalene block for shoulder surgery recovery.
  • The first local anesthetic injection did not exhibit signs of cervical epidural anesthesia, but subsequent X-ray confirmed the incorrect placement of the catheter.
  • Key preventative measures were not fully implemented, including performing the block before anesthesia, proper cannula orientation, and routine X-ray checks prior to injections.

Article Abstract

A case is reported of inadvertent insertion of a brachial plexus catheter into the cervical epidural space, at the sitting of an interscalene block for postoperative analgesia, during the recovery from general anaesthesia after surgical repair of a rupture of the rotator cuff of the shoulder. No features of cervical epidural anaesthesia were seen after the first injection of local anaesthetic, as it was made through the catheter insertion cannula. Once inserted, the catheter position was checked prior to the second injection of local anaesthetic. The X-ray obtained after catheter opacification showed the penetration of contrast medium into the epidural space. In our case, two out of the three means of prevention of this complication were not possible: a) sitting of the interscalene block before induction of anaesthesia, as the insertion conditions of the catheter are better in a conscious, sitting patient; b) adequate cannula orientation (namely medial, dorsal and slightly caudal); c) routine X-ray control of the catheter position before the first injection, associated with careful clinical monitoring for 30 min after each local anaesthetic injection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0750-7658(05)80400-9DOI Listing

Publication Analysis

Top Keywords

local anaesthetic
12
cervical epidural
8
epidural space
8
sitting interscalene
8
interscalene block
8
injection local
8
catheter position
8
catheter
6
[interscalenic block
4
block accidental
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!