In rats; following oral administration of cream and intravenous heparin, plasma free fatty acids and triiodothyronine Sephadex uptake were elevated. Simultaneously apparent serum thyroxine, measured by the Tetrasorb-E kit, was increased, but not when measured using reusable Sephadex columns. Addition of oleate to a human serum albumin solution or to human serum produced similar effects; appreciable rises in apparent thyroxine were noted in the kit assay but only minor changes occurred when Sephadex columns were used. In the latter procedure almost all [14C]oleic acid added to serum was removed in the first barbital buffer wash, before application of the thyroxine-binding globulin solution. In the serum thyroxine assay on reusable Sephadex columns, there is minimal interference by free fatty acids because they are removed by the first barbital buffer wash.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0009-8981(77)90368-0DOI Listing