Mechanical circulatory support with the Thoratec assist device in patients with postcardiotomy cardiogenic shock.

Ann Thorac Surg

Department of Thoracic and Cardiovascular Surgery, Heart Center North Rhine-Westphalia, Ruhr University of Bochum, Bad Oeynhausen, Germany.

Published: January 1996

Background: In spite of modern cardiac surgical techniques, severe cardiogenic shock not responding to pharmacologic therapy and intraaortic balloon pumping develops in about 0.2% to 1.2% of patients undergoing cardiac operations.

Methods: From September 1987 to September 1994, 184 patients were supported with different mechanical circulatory support systems. Nine patients with postcardiotomy cardiogenic shock were supported with the Thoratec ventricular assist device. Four patients suffered early postcardiotomy cardiogenic shock, and 5 patients suffered late postcardiotomy cardiogenic shock. In 6 patients the Thoratec device was applied exclusively, in 2 patients both Bio-Medicus and Thoratec, and in 1 patient both ABIOMED and Thoratec devices were used. Duration of support ranged from 5 to 46 days with a mean duration of 15 days.

Results: Four patients (44%) survived and were discharged. Main complications and causes of death were multiple organ failure and sepsis.

Conclusions: The results justify the use of Thoratec assist device in patients with severe preoperative cardiogenic shock.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0003-4975(95)01030-0DOI Listing

Publication Analysis

Top Keywords

cardiogenic shock
24
postcardiotomy cardiogenic
16
assist device
12
device patients
12
patients
10
mechanical circulatory
8
circulatory support
8
thoratec assist
8
patients postcardiotomy
8
patients suffered
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!