The report is based on the experience with surgical treatment of 126 patients having aneurysm of the abdominal aorta. The average age of the operated patients was 60. The technic of radical surgery in aneurysm of infrarenal portion of the abdominal aorta is described, as well as the methods employed.
Download full-text PDF |
Source |
---|
Diagnostics (Basel)
January 2025
Vascular Surgery Division, Department of Surgery "Paride Stefanini", Policlinico Umberto I-"La Sapienza" University of Rome, Viale del Policlinico, 00161 Rome, Italy.
: This study aimed to evaluate whether gender-related anatomical differences in proximal aortic neck morphology affect the feasibility and outcomes of endovascular aortic aneurysm repair (EVAR) in women with abdominal aortic aneurysms (AAA). : This study performed a retrospective analysis of patients electively treated by EVAR for infrarenal AAA between January 2019 and December 2023. Demographics, anatomical characteristics, and stent graft details were analyzed.
View Article and Find Full Text PDFJ Vasc Surg
January 2025
Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA. Electronic address:
Objective: As aneurysmal disease is progressive, proximal disease progression and para-anastomotic aneurysms are complications experienced after open infrarenal abdominal aortic aneurysm repair (AAA). As such, fenestrated or branched endovascular repair (F/BEVAR) may be indicated in these patients. Data describing fenestrated endovascular aneurysm repair after prior open repair are limited to institutional databases.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
April 2025
Department of Radiology and Nuclear Medicine, University Teaching and Research Hospital Lucerne, Luzern, Switzerland.
Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).
Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.
Eur Heart J
January 2025
Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, Milan, MI 20122, Italy.
Int J Surg Case Rep
January 2025
Al-Neelain University, Faculty of Medicine, Khartoum, Sudan.
Introduction And Importance: Severe aortic stenosis (AS) and chronic obstructive pulmonary disease (COPD) significantly increase perioperative morbidity and mortality. This case report discusses the challenges of managing a 75-year-old male patient with severe AS and advanced COPD undergoing elective abdominal aortic aneurysm (AAA) repair.
Case Presentation: The patient presented with a 6.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!