Bone density measurements by dual X-ray absorptiometry (DXA) of the spine can now be made precisely, but there is no uniformity in reporting results and in presenting reference data. A European Union Concerted Action therefore devised a uniform procedure for cross-calibrating and standardizing instruments, using the European spine phantom (ESP) prototype. This phantom differs in a number of respects from the final version of the ESP. Eighteen centers in nine countries obtained 1619 records (1035 women) from Caucasian subjects, aged 20-80 years, drawn from normal populations. The DXA machines used were made by the Hologic, Lunar, and Norland companies. Highly statistically significant differences were evident between populations, both in apparent rates of bone loss with age and in the spread of values about the age-adjusted means. There were small residual differences in the results obtained with the three machine brands which could have been due to the relatively large between-center population differences we observed. The alternative or additional explanation that they were attributable, in part, to the design differences between the ESP prototype and the definitive ESP, which became available after this study was completed, was shown to be a valid possibility. Results from postmenopausal women reported in relation to the years that have elapsed since menopause showed reduced population variance when compared with conventional reporting in relation to age. After cross-calibration, the center with the highest age-adjusted normal density value averaged 23% more than the center with the lowest. It is therefore crucially important to select appropriate reference data in clinical and epidemiological studies.(ABSTRACT TRUNCATED AT 250 WORDS)

Download full-text PDF

Source
http://dx.doi.org/10.1016/8756-3282(95)00224-2DOI Listing

Publication Analysis

Top Keywords

dual x-ray
8
concerted action
8
reference data
8
esp prototype
8
x-ray absorptiometry--cross-calibration
4
absorptiometry--cross-calibration normative
4
normative reference
4
reference ranges
4
ranges spine
4
spine european
4

Similar Publications

Dual-sided centripetal microgrooved poly (D,L-lactide-co-caprolactone) disk encased in immune-regulating hydrogels for enhanced bone regeneration.

Mater Today Bio

February 2025

China Uruguay Bio-Nano Pharmaceutical Joint Laboratory, Institute of Neuroregeneration and Neurorehabilitation, Qingdao University, 308 Ningxia Road, Qingdao, 266071, Shandong, China.

Well-designed artificial scaffolds are urgently needed due to the limited self-repair capacity of bone, which hampers effective regeneration in critical defects. Optimal scaffolds must provide physical guidance to recruit cells and immune regulation to improve the regenerative microenvironment. This study presents a novel scaffold composed of dual-sided centripetal microgrooved poly(D,L-lactide-co-caprolactone) (PLCL) film combined with a dynamic hydrogel containing prednisolone (PLS)-loaded Prussian blue nanoparticles (PB@PLS).

View Article and Find Full Text PDF

Introduction: Adolescents with a lower peak bone mineral density (BMD) and bone mineral content (BMC) have an elevated risk of osteoporosis in adulthood. The impact of diet on bone health, particularly its role in managing inflammation, which is a key factor in bone health, is gaining wider recognition. Despite evidence that anti-inflammatory diets can enhance bone health, the link between the dietary inflammatory index (DII) and bone health among US adolescents has not been thoroughly investigated.

View Article and Find Full Text PDF

Axial radiographic spondyloarthritis (r-axSpA) is a chronic inflammatory joint disease that leads to a considerable decline in the quality of life of patients by impairment of function and mobility, which, in turn, brings about a deterioration of both physical and mental health. Osteoporosis (OP) is a significant issue in the course of r-axSpA. Fractures resulting from OP complicate the treatment of the underlying disease and reduce the quality of life of patients.

View Article and Find Full Text PDF

Flexible covalent organic frameworks (COFs) offer distinct advantages in elasticity and adaptability over rigid COFs, but these benefits often come at the expense of crystallinity due to challenges in polymerization, complicating both synthesis and structural characterization. Current research primarily employs single flexible monomers, which limits the tunability of these frameworks. In this study, we introduce two highly crystalline, flexible COFs, ZCST-102 and ZCST-103, constructed from dual flexible monomers.

View Article and Find Full Text PDF

Objectives: This study aimed to compare the clinical efficacy of dual-time Ga-pentixafor PET/CT with adrenal vein sampling (AVS) in PA lateralization.

Methods And Methods: We retrospectively analysed 161 patients with PA. We assessed the diagnostic performance of dual-time Ga-pentixafor PET/CT in diagnosing unilateral primary aldosteronism (UPA) and aldosterone-producing adenoma (APA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!