Background: Although biological glues have been used clinically in cardiovascular operations, there are no comprehensive comparative studies to help clinicians select one glue over another. In this study we determined the efficacy in controlling suture line and surface bleeding and the biophysical properties of cryoprecipitate glue, two-component fibrin sealant, and "French" glue containing gelatin-resorcinol-formaldehyde-glutaraldehyde (GRFG).
Methods: Twenty-four dogs underwent a standardized atriotomy and aortotomy; the incisions were closed with interrupted 3-0 polypropylene sutures placed 3 mm apart. All dogs had a 3- by 3-cm area of the anterior wall of the right ventricle abraded until bleeding occurred. The animals were randomly allocated into four groups: in group 1 (n = 6) bleeding from the suture lines and from the epicardium was treated with cryoprecipitate glue; in group 2 (n = 6) bleeding was treated with two-component fibrin sealant; group 3 (n = 6) was treated with GRFG glue; group 4 (n = 6) was the untreated control group. The glues were also evaluated with regard to histomorphology, tensile strength, and virology.
Results: The cryoprecipitate glue and the two-component fibrin sealant glue were equally effective in controlling bleeding from the aortic and atrial suture lines. Although the GRFG glue slowed bleeding significantly at both sites compared to baseline, it did not provide total control. The control group required additional sutures to control bleeding. The cryoprecipitate glue and the two-component fibrin sealant provided a satisfactory clot in 3 to 4 seconds on the epicardium, whereas the GRFG glue generated a poor clot. There were minimal adhesions in the subpericardial space in the cryoprecipitate and the two-component fibrin sealant groups, whereas moderate-to-dense adhesions were present in the GRFG glue group at 6 weeks. The two-component fibrin sealant was completely reabsorbed by 10 days, but cryoprecipitate and GRFG glues were still present. On histologic examination, both fibrin glues exhibited minimal tissue reaction; in contrast, extensive fibroblastic proliferation was caused by the GRFG glue. The two-component and GRFG glues had outstanding adhesive property; in contrast, the cryoprecipitate glue did not show any adhesive power. The GRFG glue had a significantly greater tensile strength than the two-component fibrin sealant. Random samples from both cryoprecipitate and the two-component fibrin glue were free of hepatitis and retrovirus.
Conclusions: The GRFG glue should be used as a tissue reinforcer; the two-component fibrin sealer is preferable when hemostatic action must be accompanied with mechanical barrier; and finally, the cryoprecipitate glue can be used when hemostatic action is the only requirement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0003-4975(95)00599-G | DOI Listing |
J Biomater Sci Polym Ed
September 2024
Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha, India.
Protein-based hydrogels are appealing materials for a variety of therapeutic uses because they are compatible, biodegradable, and adaptable to biological and chemical changes. Therefore, adherent varieties of hydrogels have received significant study; nevertheless, the majority of them show weak mechanical characteristics, transient adherence, poor biocompatibility activity, and low tensile strength. Here we are reporting, a two-component (BSA-gelatin) protein solution crosslinked with Tetrakis (hydroxymethyl) phosphonium chloride (THPC) to form a novel hydrogel.
View Article and Find Full Text PDFEur J Pharm Sci
January 2024
Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Henan, Zhengzhou 450052, China. Electronic address:
Introduction: Arterial restenosis caused by intimal hyperplasia (IH) is a serious complication after vascular interventions. In the rat carotid balloon injury model, we injected phosphate buffer saline (PBS), rapamycin-phosphate buffer saline suspension (RPM-PBS), blank fibrin glue (FG) and rapamycin-fibrin glue (RPM-FG) around the injured carotid artery under ultrasound guidance and observed the inhibitory effect on IH.
Methods: The properties of RPM-FG in vitro were verified by scanning electron microscopy (SEM) and determination of the drug release rate.
Adv Healthc Mater
August 2023
Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.
Primary hemostasis (platelet plug formation) and secondary hemostasis (fibrin clot formation) are intertwined processes that occur upon vascular injury. Researchers have sought to target wounds by leveraging cues specific to these processes, such as using peptides that bind activated platelets or fibrin. While these materials have shown success in various injury models, they are commonly designed for the purpose of treating solely primary or secondary hemostasis.
View Article and Find Full Text PDFTransl Vis Sci Technol
June 2022
Save Sight Institute, Sydney Medical School, University of Sydney, Sydney, Australia.
Purpose: Corneal perforation is a clinical emergency that can result in blindness. Currently corneal perforations are treated either by cyanoacrylate glue which is toxic to corneal cells, or by using commercial fibrin glue for small perforations. Both methods use manual delivery which lead to uncontrolled application of the glues to the corneal surface.
View Article and Find Full Text PDFMacromol Biosci
November 2017
Regenerative Biomaterials Group, RAFT Institute of Plastic Surgery, Mount Vernon Hospital, Northwood, HA6 2RN, UK.
The aim of this study is to design a novel two-component hybrid scaffold using the fibrin/alginate porous hydrogel Smart Matrix combined to a backing layer of plasma polymerized polydimethylsiloxane (Sil) membrane to make the fibrin-based dermal scaffold more robust for the treatment of the clinically challenging pressure sores. A design criteria are established, according to which the Sil membranes are punched to avoid collection of fluid underneath. Manual peel test shows that native silicone does not attach to the fibrin/alginate component while the plasma polymerized silicone membranes are firmly bound to fibrin/alginate.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!