Effect of changes in airway surface liquid on laryngeal receptors and muscles.

Respir Physiol

Dept. of Physiology and Biophysics, University of Texas, Galveston 77555-0641, USA.

Published: July 1995

The effects of aerosolizing distilled water and isosmolal dextrose in the isolated larynx on the activity of pressure-responsive receptors and laryngeal muscles were studied in anesthetized dogs. Following water aerosolization, the mean discharge of pressure-responsive laryngeal mechanoreceptors during upper airway breathing and occlusion was 151% and 138% respectively of that present after saline aerosolization. During delivery of water aerosol, the peak activity of the posterior cricoarytenoid muscle increased to 229 +/- 56% of control; no effects were present on the thyroarytenoid muscle activity. Saline or isosmolal dextrose aerosols did not have any effect on the activity of either muscle. The reflex increase in posterior cricoarytenoid muscle activity due to laryngeal negative pressure was enhanced (163%) when the negative pressure challenge was repeated following distilled water aerosol. These results suggest that alteration in laryngeal surface liquid composition modifies the response of pressure-responsive laryngeal receptors and thereby the reflex activation of airway patency maintaining muscles.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0034-5687(95)00007-zDOI Listing

Publication Analysis

Top Keywords

surface liquid
8
laryngeal receptors
8
distilled water
8
isosmolal dextrose
8
pressure-responsive laryngeal
8
water aerosol
8
posterior cricoarytenoid
8
cricoarytenoid muscle
8
muscle activity
8
negative pressure
8

Similar Publications

PiNN: Equivariant Neural Network Suite for Modeling Electrochemical Systems.

J Chem Theory Comput

January 2025

Department of Chemistry-Ångström Laboratory, Uppsala University, Lägerhyddsvägen 1, P.O. Box 538, 75121 Uppsala, Sweden.

Electrochemical energy storage and conversion play increasingly important roles in electrification and sustainable development across the globe. A key challenge therein is to understand, control, and design electrochemical energy materials with atomistic precision. This requires inputs from molecular modeling powered by machine learning (ML) techniques.

View Article and Find Full Text PDF

Omnidirectionally Stretchable Spin-Valve Sensor Array with Stable Giant Magnetoresistance Performance.

ACS Nano

January 2025

CAS Key Laboratory of Magnetic Materials and Devices & Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, P. R. China.

Flexible magnetic sensors, which have advantages such as deformability, vector field sensing, and noncontact detection, are an important branch of flexible electronics and have significant applications in fields such as magnetosensitive electronic skin. Human skin surfaces have complicated deformations, which pose a demand for magnetic sensors that can withstand omnidirectional strain while maintaining stable performance. However, existing flexible magnetic sensor arrays can only withstand stretching along specific directions and are prone to failure under complicated deformations.

View Article and Find Full Text PDF

Liquid slide electrification: advances and open questions.

Soft Matter

January 2025

Institute for Photovoltaics, University of Stuttgart, Pfaffenwaldring 47, 70569 Stuttgart, Germany.

This review is about drops of a liquid with high dielectric permittivity that slide over a solid surface with high electrical resistivity. A typical situation is a water drop sliding down a tilted hydrophobic plate. It has been realized recently that such drops spontaneously acquire a charge.

View Article and Find Full Text PDF

Synergistic binding ability of electrostatic tweezers and femtosecond laser-structured slippery surfaces enabling unusual droplet manipulation applications.

Lab Chip

January 2025

CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, 230027, P. R. China.

We propose a novel contactless droplet manipulation strategy that combines electrostatic tweezers (ESTs) with lubricated slippery surfaces. Electrostatic induction causes the droplet to experience an electrostatic force, allowing it to move with the horizontal shift of the EST. Because both the EST and the slippery operating platform prepared by a femtosecond laser exhibit a strong binding effect on droplets, the EST droplet manipulation features significant flexibility, high precision, and can work under various operating conditions.

View Article and Find Full Text PDF

Simultaneous measurement of fentanyl, fentanyl analogues and other drugs of abuse by multiplex bead assay.

Toxicol Mech Methods

January 2025

Centers for Disease Control and Prevention, Division of Science Integration, Risk Evaluation Branch, National Institute for Occupational Safety and Health, Cincinnati, OH, USA.

Quantification of illicit drugs and controlled substances, in urine or as surface contamination, is often performed using expensive analytical techniques such as liquid chromatography with tandem mass spectrometry (LC-MS/MS). A time and cost-effective semi-quantitative surface-wipe and urine screening multiplex immunoassay for fentanyl and its analogues was developed in this investigation. We previously created a surface wipe multiplex immunoassay for methamphetamine, caffeine, cocaine, tetrahy-drocannabinol (THC) and oxycodone.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!