A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of the components of Lycopus europaeus L. in body fluids during metabolism studies. Comparison of capillary electrophoresis and high-performance liquid chromatography. | LitMetric

During pharmacokinetic studies with extracts obtained from medicinally used plants, analysis in body fluids is mainly performed by HPLC, an established separation method. In this paper high-performance capillary electrophoresis (HPCE) is investigated for its ability to separate such complex extracts. Crude extracts of Lycopus europaeus L. (Lamiaceae) are traditionally used against mild forms of hyperthyroidism. The metabolism of a 70% ethanolic extract with respect to some of its individual main components (rosmarinic and caffeic acid, luteolin-7-glucoside) and a mixture of the pure compounds were investigated using isolated perfused rat liver. After solid-phase extraction metabolites were determined using HPCE and HPLC separation techniques. A buffer solution composed of 0.05 mol l-1 Na2HPO4 at pH 7.0 with 30% acetonitrile was found to be the most suitable electrolyte for HPCE separation. The best mobile phase for isocratic HPLC was 0.03% TFA-acetonitrile (82:18, v/v). Data obtained with HPCE are in good accordance with those from HPLC; HPCE, however, is clearly more rapid and simple to perform.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0021-9673(95)00492-4DOI Listing

Publication Analysis

Top Keywords

lycopus europaeus
8
body fluids
8
capillary electrophoresis
8
hpce
5
analysis components
4
components lycopus
4
europaeus body
4
fluids metabolism
4
metabolism studies
4
studies comparison
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!