Previous studies using dynamic scintigraphy have shown that the measurement of changes in hepatic perfusion may be exploited to detect liver metastases. Similar hepatic haemodynamic changes also occur in cirrhosis, however, thereby reducing the diagnostic power of the technique. The ability of duplex colour Doppler sonography (DCDS) to differentiate between the changes in liver perfusion in patients with cirrhosis and those with hepatic metastases was assessed. Hepatic arterial and portal venous blood flows were measured in 30 control subjects, 20 patients with cirrhosis, and 55 patients with overt liver metastases. The Doppler perfusion index (DPI) (the rate of hepatic arterial to total liver blood flow) and the congestive index (ratio of the cross sectional area of the vessel to time averaged velocity of blood flow in the vessel) of the hepatic artery (HCI) and portal vein (PCI) were calculated. The hepatic arterial blood flow of the cirrhotic and metastatic groups was significantly raised compared with that of controls, and the portal venous blood flow of the former groups were reduced (p < 0.0001). The DPIs of the cirrhotic and metastatic groups were therefore significantly raised compared with those of controls (p < 0.0001). No significant difference was noted in HCI values between the three groups. The PCI values of the cirrhotic group, however, were significantly raised compared with those of controls and patients with metastases (p < 0.0001). The data suggest that DCDS measurement of PCI may be of value in differentiating between the hepatic perfusion changes caused by cirrhosis and those resulting from hepatic metastases, thereby increasing the diagnostic power of this technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1374320PMC
http://dx.doi.org/10.1136/gut.34.4.554DOI Listing

Publication Analysis

Top Keywords

blood flow
16
hepatic perfusion
12
liver metastases
12
patients cirrhosis
12
hepatic arterial
12
raised compared
12
compared controls
12
hepatic
10
perfusion changes
8
diagnostic power
8

Similar Publications

We present the case of a 74-year-old female patient with a 50 mm ascending aortic aneurysm who underwent ascending aorta replacement. During routine open heart surgery, suboptimal flow in the cardiopulmonary bypass circuit, led to the discovery of a type B aortic dissection with substantial flow in the false lumen. Conservative management was chosen, focusing on blood pressure control in the ICU.

View Article and Find Full Text PDF

Sotatercept in pulmonary hypertension and beyond.

Eur J Clin Invest

January 2025

Department of Surgical, Medical and Molecular Pathology and Critical Area, Laboratory of Biochemistry, University of Pisa, Pisa, Italy.

Sotatercept binds free activins by mimicking the extracellular domain of the activin receptor type IIA (ACTRIIA). Additional ligands are BMP/TGF-beta, GDF8, GDF11 and BMP10. The binding with activins leads to the inhibition of the signalling pathway and the deactivation of the bone morphogenic protein (BMP) receptor type 2.

View Article and Find Full Text PDF

Advancements in xenotransplantation intersecting with modern machine perfusion technology offer promising solutions to patients with liver failure providing a valuable bridge to transplantation and extending graft viability beyond current limitations. Patients facing acute or acute chronic liver failure, post-hepatectomy liver failure, or fulminant hepatic failure often require urgent liver transplants which are severely limited by organ shortage, emphasizing the importance of effective bridging approaches. Machine perfusion is now increasingly used to test and use genetically engineered porcine livers in translational studies, addressing the limitations and costs of non-human primate models.

View Article and Find Full Text PDF

Background: The pathogenesis of sepsis is thought to be linked to a dysregulated immune response, particularly that involving neutrophils. We have developed a granulocyte adsorption column as a "decoy organ," which relocates the massive inflammation in organs in the body to a blood purification column. This study was conducted to assess the safety and experimental effectiveness of granulocyte monocyte adsorption apheresis-direct hemoperfusion (G1-DHP) in the treatment of patients with sepsis, using a prospective, multicenter design.

View Article and Find Full Text PDF

Measurement and Analysis of Optical Transmission Characteristics of the Human Skull.

J Biophotonics

January 2025

Department of Emergency, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China.

The brain, as a vital part of central nervous system, receives approximately 25% of body's blood supply, making accurate monitoring of cerebral blood flow essential. While fNIRS is widely used for measuring brain physiology, complex tissue structure affects light intensity, spot size, and detection accuracy. Many studies rely on simulations with limited experimental validation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?