The role of bioelectrical impedance (BI) in estimating the pharmacokinetics and, therefore, individualized doses, of aminophylline in preterm infants (gestational age 26-35 weeks) was assessed in a two-phase study. Multiple regression analysis in the first group of neonates (phase I, n = 19) identified resistance, reactance, weight and length as optimal predictors of distribution volume (adjusted R2 = 0.84, coefficient of variation (CV) = 10.17%), and length2/impedance and postconceptual age as predictors of clearance (adjusted R2 = 0.74, CV = 26.73%). Application of these models to an independent group (phase II, n = 20) generated doses which satisfactorily achieved target theophylline loading and steady-state (SS) 'peaks' of 10 micrograms/mL and SS 'troughs' of 7.7 +/- 0.6 micrograms/mL. A better understanding of specific criteria and limitations of the impedance technique in neonates is necessary in order to refine BI measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1440-1754.1993.tb00462.xDOI Listing

Publication Analysis

Top Keywords

bioelectrical impedance
8
individualizing aminophylline
4
aminophylline doses
4
doses premature
4
premature infants
4
infants bioelectrical
4
impedance non-invasive
4
non-invasive approach
4
approach role
4
role bioelectrical
4

Similar Publications

High-impedance microwave resonators with two-photon nonlinear effects.

Nat Commun

January 2025

NanoLund and Solid State Physics, Lund University, Box 118, 22100, Lund, Sweden.

Nonlinear effects play a central role in photonics as they form the foundation for most of the device functionalities such as amplification and quantum state preparation and detection. Typically the nonlinear effects are weak and emerge only at high photon numbers with strong drive. Here we present an experimental study of a Josephson junction -based high-impedance resonator.

View Article and Find Full Text PDF

Jagim, AR, Horswill, CA, Dobbs, WC, Twohey, EE, Tinsley, GM, Fields, JB, and Jones, MT. Minimum wrestling weight for high school girls wrestling: Time to revisit minimal body fat percent. J Strength Cond Res XX(X): 000-000, 2024-The purpose of this study was to determine whether an alternative body fat percentage (BF%) could be established as a safer margin for minimal wrestling weight (MWW) determination by evaluating the distribution of BF% and MWW values naturally occurring for high school girls wrestling.

View Article and Find Full Text PDF

Dynamic EIT technology for real-time non-invasive monitoring of acute pulmonary embolism: a porcine model experiment.

Respir Res

January 2025

Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi'an, 710032, China.

Background: Acute pulmonary embolism represents the third most prevalent cardiovascular pathology, following coronary heart disease and hypertension. Its untreated mortality rate is as high as 20-30%, which represents a significant threat to patient survival. In view of the current lack of real-time monitoring techniques for acute pulmonary embolism, this study primarily investigates the potential of the pulsatility electrical impedance tomography (EIT) technique for the detection and real-time monitoring of acute pulmonary embolism through the collection and imaging of the pulsatile signal of pulmonary blood flow.

View Article and Find Full Text PDF

Background: Accurate assessment of fluid volume and hydration status is essential in many disease states, including patients with chronic kidney disease. The aim of this study was to investigate the ability of a wearable continuous bioimpedance sensor to detect changes in fluid volume in patients undergoing regular hemodialysis (HD).

Methods: 31 patients with end-stage renal disease were enrolled and monitored with a sensor patch (Re:Balans) on the upper back through two consecutive HD sessions and the interdialytic period between.

View Article and Find Full Text PDF

Background/aims: Distal mean nocturnal baseline impedance (MNBI) measuring via pH-impedance may be valuable in diagnosing patients with suspected laryngopharyngeal reflux (LPR). However, its wide adoption is hindered by cost and invasiveness. This study investigates whether baseline impedance measured during high-resolution impedance manometry (HRIM-BI) can predict pathological MNBI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!