A prototype single-screen workstation with a 2,048 x 2,560-pixel high-brightness monitor, 0.11-second image display time, and simple ergonomic design was compared to a conventional horizontal film alternator in diagnostic interpretation of chest computed tomography (CT) studies. Four radiologists used either the workstation or film alternator in interpretation of studies obtained in 10 patients. A counterbalanced within-subject repeated measures experimental design was used. Response times were analyzed for both methods of interpretation. Grades of excellent, acceptable, and unacceptable were assigned by a blinded "grader" to reports of the radiologists. The average time needed for an interpretation at the workstation was 5.65 minutes. No interpretations were graded unacceptable. Retrospective power analysis showed that 16 observers rather than four would have been required to show that use of the workstation was faster than the alternator. With this 95% confidence interval, the workstation interpretation time is clinically equivalent to that with the alternator. These data show that this type of workstation has practical application in interpretation of CT, magnetic resonance imaging, and ultrasound studies.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.187.2.8475309DOI Listing

Publication Analysis

Top Keywords

film alternator
12
interpretation studies
8
single-screen workstation
8
interpretation
7
workstation
7
alternator
5
studies single-screen
4
workstation versus
4
versus film
4
alternator prototype
4

Similar Publications

Restoring adult stereopsis: a vision researcher's personal experience.

Optom Vis Sci

June 2014

*PhD Department of Psychology, University of California, Santa Cruz, Santa Cruz, California.

In February 2012, the author acquired improved stereoscopic vision after viewing Martin Scorsese's film Hugo in 3D. The author had been deficient in stereo vision all of his life because in the first two decades, one eye deviated outward from the gaze position of the other. At that time, he was an alternator (alternating exotrope) showing strabismus (>20 prism diopters) without amblyopia.

View Article and Find Full Text PDF

Objective: The purpose of our study was to quantitatively compare the time for interpretation of screening full-field digital mammography (FFDM) images using prior analog film mammograms for comparison versus digitized prior analog mammograms.

Materials And Methods: Images from 100 FFDM studies were interpreted by four radiologists. All FFDM images had comparison analog mammograms obtained a minimum of 1 year earlier that were digitized using a 43-μm film digitizer.

View Article and Find Full Text PDF

Digital screening mammograms (DM) take longer to interpret than film-screen screening mammograms (FSM). We evaluated what part of the process takes long in our reading environment. We selected cases from those for which timed readings had been performed as part of a previous study.

View Article and Find Full Text PDF

Soft copy display requirements for digital mammography.

J Digit Imaging

September 2003

School of Information and Library Science, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3360, USA.

One of the advantages of digital mammography is to display mammograms on softcopy (electronic displays). Softcopy display of mammography is challenging because of the spatial and contrast resolution demands present in mammograms. We have designed and developed a softcopy mammography display application, Mammoview, which is capable of allowing radiologists to read mammograms as quickly and as accurately as they can on film alternators.

View Article and Find Full Text PDF

Despite the rapid progress made in the electronic design of imaging workstations for medicine, much less effort has gone into the design of environments in which such systems will be used. Based on studies of radiologist film reading sessions, considerable time will be spent working at such viewing systems. If the rooms in which the workstations are placed are not conducive to comfortable work, it will certainly not favor electronic viewing over film reading.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!