The purpose of this first patient study (phase II) was to evaluate the clinical usefulness of a new echo contrast agent at transcranial Doppler ultrasonography (US). Twenty patients were selected from a group of 242 patients undergoing conventional transcranial Doppler US who had low (n = 18) or absent (n = 2) Doppler signals from the middle cerebral artery (MCA). The extent and duration of Doppler signal increase was measured in 30 MCAs and in 14 basilar arteries following the intravenous injection of a transpulmonary galactose microparticle suspension (SH U 508 A) at three concentrations (200, 300, and 400 mg/mL). Doppler waveform analysis became possible in 93% (28 of 30) of the MCAs following injection. The maximal increase in average Doppler signal intensity (11 dB at 200 mg/mL, 15 dB at 300 mg/mL, and 17 dB at 400 mg/mL) and the increase in average duration of the signal enhancement (163 seconds at 200 mg/mL, 219 seconds at 300 mg/mL, and 240 seconds at 400 mg/mL) depended on contrast agent concentration. Doppler waveform analysis became possible in 79% (11 of 14) of the basilar arteries. The intravenous injection of this new echo contrast agent markedly increases Doppler signal intensity in patients with nondiagnostic results at conventional Doppler US.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.187.2.8475287DOI Listing

Publication Analysis

Top Keywords

contrast agent
16
transcranial doppler
12
echo contrast
12
doppler signal
12
400 mg/ml
12
doppler
10
basilar arteries
8
arteries intravenous
8
intravenous injection
8
doppler waveform
8

Similar Publications

Establishment of a Mouse Model with Cough Hypersensitivity via Inhalation of Citric Acid.

J Vis Exp

January 2025

State Key Laboratory of Respiratory Disease, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University;

Cough is one of the most common symptoms of many respiratory diseases. Chronic cough significantly impacts quality of life and imposes a considerable economic burden. Increased cough sensitivity is a pathophysiological hallmark of chronic cough.

View Article and Find Full Text PDF

For noninvasive light-based physiological monitoring, optimal wavelengths of individual tissue components can be identified using absorption spectroscopy. However, because of the lack of sensitivity of hardware at longer wavelengths, absorption spectroscopy has typically been applied for wavelengths in the visible (VIS) and near-infrared (NIR) range from 400 to 1,000 nm. Hardware advancements in the short-wave infrared (SWIR) range have enabled investigators to explore wavelengths in the ~1,000 nm to 3,000 nm range in which fall characteristic absorption peaks for lipid, protein, and water.

View Article and Find Full Text PDF

Normative measurements of the frontal nerve by magnetic resonance imaging in an Australia cohort.

Surg Radiol Anat

January 2025

Department of Ophthalmology & Visual Sciences, University of Adelaide, North Terrace, Adelaide, SA, 5000, Australia.

Purpose: To report the normative dimensions of the frontal nerve (FN) on fat-suppressed suppressed gadolinium (fs-gad) enhanced magnetic resonance imaging (MRI).

Method: A retrospective cohort study of patients who underwent coronal fs-gad T1-weighted MRI. Orbits were excluded if there was unilateral or bilateral pathology of the FN or optic nerve sheath (ONS), incomplete MRI sequences, poor image quality or indiscernible FN on radiological assessment.

View Article and Find Full Text PDF

In cardiovascular research, electromagnetic fields generated by Riga plates are utilized to study or manipulate blood flow dynamics, which is particularly crucial in developing treatments for conditions such as arterial plaque deposition and understanding blood behavior under varied flow conditions. This research predicts the flow patterns of blood enhanced with gold and maghemite nanoparticles (gold-maghemite/blood) in an electromagnetic microchannel influenced by Riga plates with a temperature gradient that decays exponentially, under sudden changes in pressure gradient. The flow modeling includes key physical influences like radiation heat emission and Darcy drag forces in porous media, with the flow mathematically represented through unsteady partial differential equations solved using the Laplace transform (LT) method.

View Article and Find Full Text PDF

Objective: This study aims to identify factors associated with the detectability of the right adrenal vein (RAV) on preoperative contrast-enhanced CT scans of adrenal venous sampling (AVS) in the era of high-resolution CT (HRCT).

Materials And Methods: In this retrospective study, 36 patients (15 men and 21 women; mean age, 56 y) who underwent preoperative contrast-enhanced CT [11 patients in HRCT with 0.25 mm detector matrix (Cannon Medical Systems) and 25 patients in conventional multidetector CT with 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!