The use of magnetic resonance (MR) velocity mapping in the quantification of aortic valvular blood flow was examined in 10 patients with angiographically verified aortic regurgitation. MR velocity mapping succeeded in identifying and quantifying the regurgitation in all patients, and the regurgitant volume determined with MR velocity mapping agreed well with the grade obtained by aortic root angiography (p < 0.02). The accuracy in quantification of the aortic valvular flow rate was demonstrated by a significant correlation between the stroke volume (ml) measured by MR velocity mapping and calculated from MR imaging of the left ventricular end-diastolic and end-systolic volumes in eight patients (Y = 0.89 x X + 11, r = 0.97, p < 0.001). This finding was confirmed by a good agreement between the net cardiac output (L/min) quantified with MR velocity mapping and simultaneous 125I-indicator dilution measurement in all subjects (Y = 0.89 x X + 0.08, r = 0.82, p < 0.01). In conclusion, MR velocity mapping may be used as a noninvasive tool in the quantification of aortic regurgitation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0002-8703(93)90117-r | DOI Listing |
Phys Med Biol
January 2025
Schlegel Research Institute for Aging, University of Waterloo, 250 Laurelwood Drive, Waterloo, Ontario, N2L 3G1, CANADA.
As ultrasound-compatible flow phantoms are devised for performance testing and calibration, there is a practical need to obtain independent flow measurements for validation using a gold-standard technique such as particle image velocimetry (PIV). In this paper, we present the design of a new dual-modality flow phantom that allows ultrasound and PIV measurements to be simultaneously performed. Our phantom's tissue mimicking material is based on a novel hydrogel formula that uses propylene glycol to lower the freezing temperature of an ultrasound-compatible poly(vinyl) alcohol cryogel and, in turn, maintain the solution's optical transparency after thermocycling.
View Article and Find Full Text PDFRecent advancements in flexible bioelectronics have enabled continuous, long-term stable interrogation and intervention of biological systems. However, effectively utilizing the interrogated data to modulate biological systems to achieve specific biomedical and biological goals remains a challenge. In this study, we introduce an AI-driven bioelectronics system that integrates tissue-like, flexible bioelectronics with cyber learning algorithms to create a long-term, real-time bidirectional b ioelectronic interface with o ptimized a daptive intelligent m odulation (BIO-AIM).
View Article and Find Full Text PDFThis study aims to evaluate cerebrospinal fluid (CSF) flow dynamics within ventricles, and the subarachnoid space (SAS) using the velocity selective spin labeling (VSSL) MRI method with Fourier-transform-based velocity selective inversion preparation. The study included healthy volunteers who underwent MRI scanning with specific VSSL parameters optimized for CSF flow quantification. The VSSL sequence was calibrated against phase-contrast MRI (PC-MRI) to ensure accurate flow velocity measurements.
View Article and Find Full Text PDFJ Strength Cond Res
December 2024
Department of Sports Science and Physical Education, Nord University, Levanger, Norway.
Gundersen, AH, van den Tillaar, R, Falch, HN, Fredriksen, AB, and Larsen, S. A biomechanical comparison between conventional, sumo, and hex-bar deadlifts among resistance trained women. J Strength Cond Res XX(X): 000-000, 2024-The deadlift is a multijoint exercise frequently used to strengthen the lower extremities and spinal erectors.
View Article and Find Full Text PDFJ Physiol
December 2024
School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA.
Previous studies established strong links between morphological characteristics of mammalian hindlimb muscles and their sensorimotor functions during locomotion. Less is known about the role of forelimb morphology in motor outputs and generation of sensory signals. Here, we measured morphological characteristics of 46 forelimb muscles from six cats.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!