We tested the utility of a novel collection system that allows measurement of theophylline in oral mucosal transudate (OMT) to calculate serum theophylline concentrations. In 25 adult patients, theophylline levels in OMT correlated better than expectorated saliva with serum theophylline (r = 0.927 for OMT versus r = 0.831 for expectorated saliva, each p < 0.0001). In a subsequent study of 128 patients (118 adults and 10 children aged 4 to 12 yr), OMT and serum theophylline were measured and polynomial regression analysis performed to allow calculation of serum level for any given OMT level. Theophylline levels calculated from OMT values closely followed measured serum theophylline in two normal subjects after administration of either intravenous or oral theophylline. OMT samples collected by 24 patients at home were mailed to the laboratory for testing. Theophylline values from the home collection samples correlated closely (r = 0.930, p < 0.0001) with serum theophylline levels obtained at the same dose of theophylline. These findings suggest that once the relationship of serum to OMT theophylline is established in a given laboratory, the latter can be used to monitor outpatient theophylline therapy in adults (and possibly children) at times of the day otherwise inaccessible to serum sampling.

Download full-text PDF

Source
http://dx.doi.org/10.1164/ajrccm/147.3.739DOI Listing

Publication Analysis

Top Keywords

serum theophylline
20
theophylline
14
theophylline levels
12
theophylline oral
8
oral mucosal
8
mucosal transudate
8
omt
8
serum
8
expectorated saliva
8
adults children
8

Similar Publications

Looking at the albumin-drug binding via partitioning in aqueous two-phase system.

Biochem Biophys Res Commun

January 2025

Cleveland Diagnostics, 3615 Superior Ave., Cleveland, OH, 44114, USA. Electronic address:

The partition coefficient of human serum albumin (HSA) was analyzed in the PEG600-Dex70, 0.15 M NaCl/KCl in 0.01 M Na/K phosphate buffer, pH 7.

View Article and Find Full Text PDF
Article Synopsis
  • Acute kidney injury (AKI) is a common complication in neonates who experience severe perinatal asphyxia, and the role of aminophylline in preventing it is debated.
  • A study involving 81 severely asphyxiated term neonates evaluated the effectiveness of aminophylline as an adjunct to standard care, showing a lower but not statistically significant incidence of AKI in the aminophylline group compared to the control group.
  • While aminophylline treatment seemed to temporarily improve urine output, it did not significantly change renal function or lower AKI rates overall.
View Article and Find Full Text PDF

Objective: To conduct an exhaustive scoping search of existing literature, incorporating diverse bibliographic sources to elucidate the relationships between metabolite biomarkers in human fluids and dietary intake.

Background: The search for biomarkers linked to specific dietary food intake holds immense significance for precision health and nutrition research. Using objective methods to track food consumption through metabolites offers a more accurate way to provide dietary advice and prescriptions on healthy dietary patterns by healthcare professionals.

View Article and Find Full Text PDF

Background: Previous studies reported that variations in dietary intake patterns substantially impact human health, specifically tumorigenesis. However, confounding factors in previous cohort studies have obscured the relationship between dietary differences and the risk of oral cancer (OC).

Materials And Methods: We developed an outcome dataset from genome-wide association studies (GWAS) data on three OCs within the GAME-ON project, using GWAS-META merging.

View Article and Find Full Text PDF

A candidate reference measurement procedure (RMP) for serum theophylline via isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. With a single-step precipitation pretreatment and a 6-min gradient elution, the method achieved baseline separation of theophylline and its analogs on a C18-packed column. A bracketing calibration method was used to ensure repeatable signal intensity and high measurement precision.

View Article and Find Full Text PDF