False desaturation due to intradermal patent blue dye.

Anesthesiology

Department of Anesthesia, Bowman Gray School of Medicine, Wake Forest University, Winston-Salem, North Carolina 27157-1009.

Published: February 1993

Download full-text PDF

Source
http://dx.doi.org/10.1097/00000542-199302000-00022DOI Listing

Publication Analysis

Top Keywords

false desaturation
4
desaturation intradermal
4
intradermal patent
4
patent blue
4
blue dye
4
false
1
intradermal
1
patent
1
blue
1
dye
1

Similar Publications

Background: False flax, or gold-of-pleasure (Camelina sativa) is an oilseed that has received renewed research interest as a promising vegetable oil feedstock for liquid biofuel production and other non-food uses. This species has also emerged as a model for oilseed biotechnology research that aims to enhance seed oil content and fatty acid quality. To date, a number of genetic engineering and gene editing studies on C.

View Article and Find Full Text PDF

Background: Anastomotic leak (AL) in upper gastrointestinal (UGI) surgery continues to be a diagnostic challenge. We seek to identify clinical parameters that predict AL and examine the effectiveness of investigations in evaluating AL following UGI surgeries.

Methods: 592 patients underwent UGI surgeries with an anastomosis between January 2011 and January 2021.

View Article and Find Full Text PDF

Importance: Propofol sedation is widely used for endoscopic procedures, but it poses risks of hemodynamic and respiratory depression. The addition of esketamine as an adjuvant may reduce propofol requirements and associated adverse events.

Objective: To evaluate the effects of low-dose esketamine added to propofol-based sedation on desaturation and hypotension during same-visit bidirectional endoscopy.

View Article and Find Full Text PDF

Standard pulse oximeters estimate arterial blood saturation (SaO) non-invasively by emitting and detecting light of a specific wavelength through a cutaneous vascular bed, such as a digit or the ear lobe. The quantity measured at these peripheral sites is designated as oxygen saturation (SpO). Most reliable pulse oximeters are calibrated from measurements of healthy volunteers using some form of oxygen desaturation method.

View Article and Find Full Text PDF

Unlabelled: Hallucinations are false sensory perceptions that occur in the absence of an external stimulus. Three cases of hallucinations related to obstructive sleep apnea-hypopnea syndrome are reported, 2 of which improved with the initiation of continuous positive airway pressure therapy. So far there are no published reports in the literature that account for this relationship in the absence of primary or structural mental pathology.